Non-contact radar-based HRV monitoring method using adaptive cycle segmentation and peak extraction

Heart rate variability (HRV), as a key indicator for evaluating autonomic nervous system function, has significant value in areas such as cardiovascular disease screening and emotion monitoring. Although traditional contact-based measurement methods offer high precision, they suffer from issues such as poor comfort and low user compliance. This paper proposes a non-contact HRV monitoring method using frequency modulated continuous wave (FMCW) radar, highlighting adaptive cycle segmentation and peak extraction as core innovations. Key advantages of this method include: 1) effective suppression of motion artifacts and respiratory harmonics by leveraging cardiac energy concentration; 2) precise heartbeat cycle identification across physiological states via adaptive segmentation, addressing time-varying differences; 3) adaptive threshold adjustment using discrete energy signals and a support vector machine (SVM) model based on morphological-temporal-spectral characteristics, reducing complexity while maintaining precision. Previous approaches predominantly process radar signals holistically through algorithms to uniformly extract inter-beat intervals (IBIs), which may result in high computational complexity and inadequate dynamic adaptability. In contrast, our method achieved higher precision than conventional holistic processing approaches, while maintaining comparable precision with lower computational complexity than previous optimization algorithms. Experimental results demonstrate that the system achieves an average IBI error of 8.28 ms (RMSE of 15.3 ms), which is reduced by about 66% compared with the traditional holistically peak seeking method. The average errors of SDNN and RMSSD are 2.65 ms and 4.33 ms, respectively. More than 92% of the IBI errors are controlled within 20 ms. The distance adaptability test showed that although the accuracy of long-distance measurement decreased slightly (<6 ms), the overall detection performance remained robust at different distances. This study provided a novel estimation algorithm for non-contact HRV detection, offering new perspectives for future health monitoring.

Authors

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-contact radar-based HRV monitoring method using adaptive cycle segmentation and peak extraction

Liang Junge, Li Mingchao, Yu Tian, ZHU Xinxing et al.
SHILAP Revista de lepidopterología
Non-Invasive Vital Sign Monitoring
article

Non-contact radar-based HRV monitoring method using adaptive cycle segmentation and peak extraction

Liang Junge, Li Mingchao, Yu Tian, ZHU Xinxing, WU Enkang, WANG Cong, GAO Yixuan, GU Xiaofeng
article en

Abstract

Heart rate variability (HRV), as a key indicator for evaluating autonomic nervous system function, has significant value in areas such as cardiovascular disease screening and emotion monitoring. Although traditional contact-based measurement methods offer high precision, they suffer from issues such as poor comfort and low user compliance. This paper proposes a non-contact HRV monitoring method using frequency modulated continuous wave (FMCW) radar, highlighting adaptive cycle segmentation and peak extraction as core innovations. Key advantages of this method include: 1) effective suppression of motion artifacts and respiratory harmonics by leveraging cardiac energy concentration; 2) precise heartbeat cycle identification across physiological states via adaptive segmentation, addressing time-varying differences; 3) adaptive threshold adjustment using discrete energy signals and a support vector machine (SVM) model based on morphological-temporal-spectral characteristics, reducing complexity while maintaining precision. Previous approaches predominantly process radar signals holistically through algorithms to uniformly extract inter-beat intervals (IBIs), which may result in high computational complexity and inadequate dynamic adaptability. In contrast, our method achieved higher precision than conventional holistic processing approaches, while maintaining comparable precision with lower computational complexity than previous optimization algorithms. Experimental results demonstrate that the system achieves an average IBI error of 8.28 ms (RMSE of 15.3 ms), which is reduced by about 66% compared with the traditional holistically peak seeking method. The average errors of SDNN and RMSSD are 2.65 ms and 4.33 ms, respectively. More than 92% of the IBI errors are controlled within 20 ms. The distance adaptability test showed that although the accuracy of long-distance measurement decreased slightly (<6 ms), the overall detection performance remained robust at different distances. This study provided a novel estimation algorithm for non-contact HRV detection, offering new perspectives for future health monitoring.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 36%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Non-contact radar-based HRV monitoring method using adaptive cycle segmentation and peak extraction — Liang Junge, Li Mingchao, et al. · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS