Motion intention recognition using surface electromyography and arrayed flexible thin-film pressure sensors

Motion intention recognition is considered the key technology for enhancing the training effectiveness of upper limb rehabilitation robots for stroke patients, but traditional recognition systems are difficult to simultaneously balance real-time performance and reliability. To achieve real-time and accurate upper limb motion intention recognition, a multi-modal fusion method based on surface electromyography (sEMG) signals and arrayed flexible thin-film pressure (AFTFP) sensors was proposed. Through experimental tests on 10 healthy subjects (5 males and 5 females, age 23±2 years), sEMG signals and human-machine interaction force (HMIF) signals were collected during elbow flexion, extension, and shoulder internal and external rotation. The AFTFP signals based on dynamic calibration compensation and the sEMG signals were processed for feature extraction and fusion, and the recognition performance of single signals and fused signals was compared using a support vector machine (SVM). The experimental results showed that the sEMG signals consistently appeared 175±25 ms earlier than the HMIF signals (<italic>p</italic>&lt;0.01, paired <italic>t</italic>-test). In offline conditions, the recognition accuracy of the fused signals exceeded 99.77% across different time windows. Under a 0.1 s time window, the real-time recognition accuracy of the fused signals was 14.1% higher than that of the single sEMG signal, and the system’s end-to-end delay was reduced to less than 100 ms. The AFTFP sensor is applied to motion intention recognition for the first time. And its low-cost, high-density array design provided an innovative solution for rehabilitation robots. The findings demonstrate that the AFTFP sensor adopted in this study effectively enhances intention recognition performance. The fusion of its output HMIF signals with sEMG signals combines the advantages of both modalities, enabling real-time and accurate motion intention recognition. This provides efficient command output for human-machine interaction in scenarios such as stroke rehabilitation.

Authors

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-12-01
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Motion intention recognition using surface electromyography and arrayed flexible thin-film pressure sensors

LIN Mingxing, YIN Xiangguo, BU Lingyu, LIU Jiahe
SHILAP Revista de lepidopterología
Stroke Rehabilitation and Recovery
article

Motion intention recognition using surface electromyography and arrayed flexible thin-film pressure sensors

LIN Mingxing, YIN Xiangguo, BU Lingyu, LIU Jiahe
article en

Abstract

Motion intention recognition is considered the key technology for enhancing the training effectiveness of upper limb rehabilitation robots for stroke patients, but traditional recognition systems are difficult to simultaneously balance real-time performance and reliability. To achieve real-time and accurate upper limb motion intention recognition, a multi-modal fusion method based on surface electromyography (sEMG) signals and arrayed flexible thin-film pressure (AFTFP) sensors was proposed. Through experimental tests on 10 healthy subjects (5 males and 5 females, age 23±2 years), sEMG signals and human-machine interaction force (HMIF) signals were collected during elbow flexion, extension, and shoulder internal and external rotation. The AFTFP signals based on dynamic calibration compensation and the sEMG signals were processed for feature extraction and fusion, and the recognition performance of single signals and fused signals was compared using a support vector machine (SVM). The experimental results showed that the sEMG signals consistently appeared 175±25 ms earlier than the HMIF signals (<italic>p</italic>&lt;0.01, paired <italic>t</italic>-test). In offline conditions, the recognition accuracy of the fused signals exceeded 99.77% across different time windows. Under a 0.1 s time window, the real-time recognition accuracy of the fused signals was 14.1% higher than that of the single sEMG signal, and the system’s end-to-end delay was reduced to less than 100 ms. The AFTFP sensor is applied to motion intention recognition for the first time. And its low-cost, high-density array design provided an innovative solution for rehabilitation robots. The findings demonstrate that the AFTFP sensor adopted in this study effectively enhances intention recognition performance. The fusion of its output HMIF signals with sEMG signals combines the advantages of both modalities, enabling real-time and accurate motion intention recognition. This provides efficient command output for human-machine interaction in scenarios such as stroke rehabilitation.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 26%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.