Surgical fixation of proximal splint bone fractures in horses using a 3.5‐mm LCP: A case series

Summary Background Proximal fractures of the small metacarpal/metatarsal bones (splint bones) in horses are less frequent but clinically challenging due to their close association with adjacent joints, ligamentous attachments and the suspensory apparatus. These fractures are frequently comminuted, may involve open wounds and are associated with a risk of joint instability, chronic lameness and poor athletic outcome. Several treatment options have been described. Objectives To describe the surgical technique and clinical outcome of horses with proximal splint bone fractures treated using a 3.5‐mm narrow locking compression plate (LCP). Study Design Retrospective case series. Methods Medical records of horses undergoing internal fixation of proximal splint bone fractures using a 3.5‐mm narrow LCP were reviewed. Data collected included signalment, fracture configuration, imaging findings, surgical technique, postoperative management, complications and short‐ as well as long‐term outcome. Outcome was assessed through clinical re‐examination at the clinic and follow‐up communication with owners and referring veterinarians. Results Seven horses with proximal lateral splint bone fractures were included. Four fractures were open at presentation. Stable fracture fixation was achieved in all cases. No major intra‐operative or early postoperative complications occurred. All horses returned to their intended level of activity within 4–18 months (median 9 months). Implant removal was required in two horses due to persistent lameness, which resolved following additional surgical intervention. Main Limitations The retrospective nature of the study; low case number, no direct comparison with other treatment modalities like conservative versus surgical or between surgical options. Conclusions The use of a 3.5‐mm narrow LCP plate provides a stable fracture fixation for proximal splint bone fractures with no major complications observed, even in open fractures and allowed a return to full function for the cases included in this study.

Authors

Publication Details

Journal
Equine Veterinary Education
Published
2026-03-26
DOI
https://doi.org/10.1111/eve.70088
Primary Topic
Veterinary Equine Medical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surgical fixation of proximal splint bone fractures in horses using a 3.5‐mm LCP: A case series

S. Tettke, E.‐M. Kruse, A. Noguera Cender
Equine Veterinary Education
Veterinary Equine Medical Research
article

Surgical fixation of proximal splint bone fractures in horses using a 3.5‐mm LCP: A case series

S. Tettke, E.‐M. Kruse, A. Noguera Cender
article en

Abstract

Summary Background Proximal fractures of the small metacarpal/metatarsal bones (splint bones) in horses are less frequent but clinically challenging due to their close association with adjacent joints, ligamentous attachments and the suspensory apparatus. These fractures are frequently comminuted, may involve open wounds and are associated with a risk of joint instability, chronic lameness and poor athletic outcome. Several treatment options have been described. Objectives To describe the surgical technique and clinical outcome of horses with proximal splint bone fractures treated using a 3.5‐mm narrow locking compression plate (LCP). Study Design Retrospective case series. Methods Medical records of horses undergoing internal fixation of proximal splint bone fractures using a 3.5‐mm narrow LCP were reviewed. Data collected included signalment, fracture configuration, imaging findings, surgical technique, postoperative management, complications and short‐ as well as long‐term outcome. Outcome was assessed through clinical re‐examination at the clinic and follow‐up communication with owners and referring veterinarians. Results Seven horses with proximal lateral splint bone fractures were included. Four fractures were open at presentation. Stable fracture fixation was achieved in all cases. No major intra‐operative or early postoperative complications occurred. All horses returned to their intended level of activity within 4–18 months (median 9 months). Implant removal was required in two horses due to persistent lameness, which resolved following additional surgical intervention. Main Limitations The retrospective nature of the study; low case number, no direct comparison with other treatment modalities like conservative versus surgical or between surgical options. Conclusions The use of a 3.5‐mm narrow LCP plate provides a stable fracture fixation for proximal splint bone fractures with no major complications observed, even in open fractures and allowed a return to full function for the cases included in this study.

Equine Veterinary Education
Openalex Percentile: Top 2%
Veterinary Equine Medical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.