An approach for merging colored dissolved organic matter absorption measurements from complementary benchtop spectrometers

Abstract Absorption of light by colored dissolved organic matter (CDOM) is often measured for in situ samples using benchtop spectrophotometers, whose valid wavelength ranges are set by the CDOM concentration of the sample and by instrument constraints such as linear response limit and instrument uncertainty. As tools for algorithm development, calibration, and validation, these measurements are most useful when they report CDOM absorption coefficients across the greatest wavelength range, which often means extending further into ultraviolet wavelengths. To maximize the reported spectral range while delivering the highest‐quality measurements across ultraviolet–visible wavelengths we developed and evaluated two approaches, the value threshold and percent difference approaches, to combine CDOM absorption spectra of the same sample measured on two different spectrophotometers that have different but overlapping spectral ranges. Colored dissolved organic matter absorption measurements from 1001 samples were examined, which were sourced from nine different field campaigns with broad optical water type properties. The value threshold approach successfully produces a merged product with larger spectral range for coastal ocean and open ocean samples, transitioning between the input measurements over a span of 40–80 nm where both measurements are valid based on the instrument characteristics of linear response limit and instrument uncertainty. The percent difference approach relies on the percent difference between spectra from the two instruments and works for coastal ocean waters but fails for most open ocean samples where there is more uncertainty proportional to CDOM signal. The value threshold approach can be modified to reduce noise propagation in the merged product and can also be adapted for use with other benchtop spectrometer models, making it highly generalizable.

Authors

Institutions

Publication Details

Journal
Limnology and Oceanography Methods
Published
2026-03-26
DOI
https://doi.org/10.1002/lom3.70044
Primary Topic
Marine and coastal ecosystems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An approach for merging colored dissolved organic matter absorption measurements from complementary benchtop spectrometers

Graham Trolley, Antonio Mannino, Kelsey Allen
Limnology and Oceanography Methods
Marine and coastal ecosystems
article

An approach for merging colored dissolved organic matter absorption measurements from complementary benchtop spectrometers

Graham Trolley, Antonio Mannino, Kelsey Allen
article en

Abstract

Abstract Absorption of light by colored dissolved organic matter (CDOM) is often measured for in situ samples using benchtop spectrophotometers, whose valid wavelength ranges are set by the CDOM concentration of the sample and by instrument constraints such as linear response limit and instrument uncertainty. As tools for algorithm development, calibration, and validation, these measurements are most useful when they report CDOM absorption coefficients across the greatest wavelength range, which often means extending further into ultraviolet wavelengths. To maximize the reported spectral range while delivering the highest‐quality measurements across ultraviolet–visible wavelengths we developed and evaluated two approaches, the value threshold and percent difference approaches, to combine CDOM absorption spectra of the same sample measured on two different spectrophotometers that have different but overlapping spectral ranges. Colored dissolved organic matter absorption measurements from 1001 samples were examined, which were sourced from nine different field campaigns with broad optical water type properties. The value threshold approach successfully produces a merged product with larger spectral range for coastal ocean and open ocean samples, transitioning between the input measurements over a span of 40–80 nm where both measurements are valid based on the instrument characteristics of linear response limit and instrument uncertainty. The percent difference approach relies on the percent difference between spectra from the two instruments and works for coastal ocean waters but fails for most open ocean samples where there is more uncertainty proportional to CDOM signal. The value threshold approach can be modified to reduce noise propagation in the merged product and can also be adapted for use with other benchtop spectrometer models, making it highly generalizable.

Limnology and Oceanography Methods
Goddard Space Flight Center (US), Science Systems and Applications (United States) (US)
Life below water
Openalex Percentile: Top 4%
Marine and coastal ecosystems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.