Exergy-informed collaborative control of refrigerant-based integrated thermal management systems for electric vehicles

• Design of a refrigerant-based integrated thermal management system architecture. • The collaborative control strategy achieved active cooling capacity distribution. • Enabling good temperature control and energy efficiency. • Exergy analysis was used to guide improvements of control strategies. Refrigerant direct cooling (RDC) faces significant challenges in uneven cooling capacity distribution and strong cabin-battery thermal coupling, which limits its widespread application in integrated thermal management systems (ITMS). To address this issue, this study proposes an ITMS architecture based on dual evaporators and variable opening valves (VOVs), and develops a collaborative control strategy for the compressor and VOVs incorporating exergy analysis. A numerical model of the ITMS was established to quantitatively evaluate the thermal and energy consumption characteristics under different control strategies. Results indicate that, compared with compressor control, the collaborative control strategy achieves active cooling distribution and significantly mitigates subsystem coupling effects. Based on the main sources of exergy destruction identified through exergy analysis, directions for optimizing the control strategy are provided. The improved strategies suppress the battery temperature rise, reduce the battery temperature difference, and maintain the maximum cabin temperature fluctuation within 0.56 °C. Compared to the baseline control strategy, the improved strategies achieve a maximum COP increase of 44.83% and a maximum system exergy destruction reduction of 52.6%. This study validates the feasibility and engineering value of exergy analysis-based collaborative control in enhancing system energy efficiency and decoupling multi-heat source management.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2026-03-28
DOI
https://doi.org/10.1016/j.tsep.2026.104669
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exergy-informed collaborative control of refrigerant-based integrated thermal management systems for electric vehicles

Tianshi Zhang, Xue Gao, Chun Gao, Qing Gao
Thermal Science and Engineering Progress
Refrigeration and Air Conditioning Technologies
article

Exergy-informed collaborative control of refrigerant-based integrated thermal management systems for electric vehicles

Tianshi Zhang, Xue Gao, Chun Gao, Qing Gao
article en

Abstract

• Design of a refrigerant-based integrated thermal management system architecture. • The collaborative control strategy achieved active cooling capacity distribution. • Enabling good temperature control and energy efficiency. • Exergy analysis was used to guide improvements of control strategies. Refrigerant direct cooling (RDC) faces significant challenges in uneven cooling capacity distribution and strong cabin-battery thermal coupling, which limits its widespread application in integrated thermal management systems (ITMS). To address this issue, this study proposes an ITMS architecture based on dual evaporators and variable opening valves (VOVs), and develops a collaborative control strategy for the compressor and VOVs incorporating exergy analysis. A numerical model of the ITMS was established to quantitatively evaluate the thermal and energy consumption characteristics under different control strategies. Results indicate that, compared with compressor control, the collaborative control strategy achieves active cooling distribution and significantly mitigates subsystem coupling effects. Based on the main sources of exergy destruction identified through exergy analysis, directions for optimizing the control strategy are provided. The improved strategies suppress the battery temperature rise, reduce the battery temperature difference, and maintain the maximum cabin temperature fluctuation within 0.56 °C. Compared to the baseline control strategy, the improved strategies achieve a maximum COP increase of 44.83% and a maximum system exergy destruction reduction of 52.6%. This study validates the feasibility and engineering value of exergy analysis-based collaborative control in enhancing system energy efficiency and decoupling multi-heat source management.

Thermal Science and Engineering ProgressVol. 73
Jilin University (CN), First Automotive Works (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 5%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.