SRS117 - Factors influencing the use of patient-specific instrumentation in shoulder arthroplasty

Abstract Introduction Patient Specific Instrumentation (PSI) has become a valuable tool in shoulder arthroplasty, especially for glenoid component placement. This study aimed to identify key factors influencing PSI use in shoulder arthroplasty. Methods A retrospective analysis of 191 anatomic and reverse total shoulder arthroplasty (aTSA, rTSA) cases performed between 2021–2024 by two senior upper limb consultants at The Royal Wolverhampton NHS Trust. All procedures used the Zimmer Biomet system with pre-operative planning via Signature ONE software. Recorded parameters included patient demographics, surgical side, glenoid anteroposterior (AP) diameter, vault depth, retroversion, and superior inclination. Statistical analysis was conducted using SPSS (V16). Results PSI was used in 64.7% (101/156) of rTSA cases and 42.9% (15/35) of aTSA cases. No significant association was found between PSI usage and age, sex, or surgical side. Increased glenoid retroversion (Median [IQR] 9.5 [5–13.87]) and superior inclination (96.75 [3.62–12.37]) were significantly associated with PSI use (P < 0.05). Although reduced glenoid AP diameter and vault depth showed a trend towards PSI use, they were not statistically significant (AP diameter: P = 0.824; vault depth: P = 0.282). PSI was significantly more likely in cases requiring medium (86.9%) or large (58.9%) glenoid augments (P < 0.001), facilitating the use of a larger central screw (≥30 mm) in 86.6% of cases. Conclusions PSI use in shoulder arthroplasty is primarily influenced by glenoid morphology, particularly retroversion, superior inclination, and augmentation requirements. Its application enhances intra-operative precision and may support improved fixation in anatomically complex cases.

Authors

Institutions

Publication Details

Journal
British journal of surgery
Published
2026-03-01
DOI
https://doi.org/10.1093/bjs/znag018.113
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SRS117 - Factors influencing the use of patient-specific instrumentation in shoulder arthroplasty

Srikiran Thalanki, Adam Daneshyar, Tim McBride, Alan M. Simons
British journal of surgery
Shoulder Injury and Treatment
article

SRS117 - Factors influencing the use of patient-specific instrumentation in shoulder arthroplasty

Srikiran Thalanki, Adam Daneshyar, Tim McBride, Alan M. Simons
article en

Abstract

Abstract Introduction Patient Specific Instrumentation (PSI) has become a valuable tool in shoulder arthroplasty, especially for glenoid component placement. This study aimed to identify key factors influencing PSI use in shoulder arthroplasty. Methods A retrospective analysis of 191 anatomic and reverse total shoulder arthroplasty (aTSA, rTSA) cases performed between 2021–2024 by two senior upper limb consultants at The Royal Wolverhampton NHS Trust. All procedures used the Zimmer Biomet system with pre-operative planning via Signature ONE software. Recorded parameters included patient demographics, surgical side, glenoid anteroposterior (AP) diameter, vault depth, retroversion, and superior inclination. Statistical analysis was conducted using SPSS (V16). Results PSI was used in 64.7% (101/156) of rTSA cases and 42.9% (15/35) of aTSA cases. No significant association was found between PSI usage and age, sex, or surgical side. Increased glenoid retroversion (Median [IQR] 9.5 [5–13.87]) and superior inclination (96.75 [3.62–12.37]) were significantly associated with PSI use (P < 0.05). Although reduced glenoid AP diameter and vault depth showed a trend towards PSI use, they were not statistically significant (AP diameter: P = 0.824; vault depth: P = 0.282). PSI was significantly more likely in cases requiring medium (86.9%) or large (58.9%) glenoid augments (P < 0.001), facilitating the use of a larger central screw (≥30 mm) in 86.6% of cases. Conclusions PSI use in shoulder arthroplasty is primarily influenced by glenoid morphology, particularly retroversion, superior inclination, and augmentation requirements. Its application enhances intra-operative precision and may support improved fixation in anatomically complex cases.

British journal of surgeryVol. 113(Supplement_2)
Dudley Group NHS Foundation Trust (GB), The Royal Wolverhampton NHS Trust (GB)
Openalex Percentile: Top 4%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.