Impact of Horizontal and Vertical Rings on the Seismic Performance of Steel Tanks under Water Sloshing Effects

The combined responses of horizontal and vertical reinforcing rings to sloshing behavior in cylindrical steel tanks subjected to seismic excitations have been evaluated in this study. In this study, for the first time, the ratio of maximum stress to fluid height in different scenarios is investigated, and the effect of water level and the stress created in the tank wall are presented, which can be a basis for improving structural design. So, the phenomenon of sloshing water on cylindrical tanks was investigated in four different situations: tanks in their original state, with horizontal rings, with vertical rings, and with both. Seismic amplification of sloshing is a very important failure mechanism in these tanks. In this case, the system undergoes resonance at the tank’s fundamental frequency, and the seismic excitation can significantly amplify the sloshing effect, cause larger-than-expected fluid movement and increase the likelihood of tank failure. Sometimes, the rapid fluid discharge creates a relative vacuum above the fluid level, which affects the upper parts of the tank shell. This study investigates the influence of horizontal and vertical rings on steel tank performance, focusing on sloshing behavior. The results of this study indicate that horizontal and vertical rings significantly influence the seismic performance of steel tanks, considering the effect of water sloshing, and a water level at half the tank’s height is optimal for withstanding seismic events. Also, it was found that if the height of the fluid is 58% of the tank height in all four cases, the highest stress will be created in the tank wall under the effect of turbulence. Examining the stress created at different heights showed that if the water level in the tank is more than one-sixth of the height of the tank, the average ratio of the highest stress level to the height of the water in the tank will be about 0.93.

Authors

Institutions

Publication Details

Journal
Journal of structural design and construction practice.
Published
2026-03-27
DOI
https://doi.org/10.1061/jsdccc.sceng-2047
Primary Topic
Fluid Dynamics Simulations and Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Horizontal and Vertical Rings on the Seismic Performance of Steel Tanks under Water Sloshing Effects

Amir Masoumi Verki, Adolfo Preciado
Journal of structural design and construction practice.
Fluid Dynamics Simulations and Interactions
article

Impact of Horizontal and Vertical Rings on the Seismic Performance of Steel Tanks under Water Sloshing Effects

Amir Masoumi Verki, Adolfo Preciado
article en

Abstract

The combined responses of horizontal and vertical reinforcing rings to sloshing behavior in cylindrical steel tanks subjected to seismic excitations have been evaluated in this study. In this study, for the first time, the ratio of maximum stress to fluid height in different scenarios is investigated, and the effect of water level and the stress created in the tank wall are presented, which can be a basis for improving structural design. So, the phenomenon of sloshing water on cylindrical tanks was investigated in four different situations: tanks in their original state, with horizontal rings, with vertical rings, and with both. Seismic amplification of sloshing is a very important failure mechanism in these tanks. In this case, the system undergoes resonance at the tank’s fundamental frequency, and the seismic excitation can significantly amplify the sloshing effect, cause larger-than-expected fluid movement and increase the likelihood of tank failure. Sometimes, the rapid fluid discharge creates a relative vacuum above the fluid level, which affects the upper parts of the tank shell. This study investigates the influence of horizontal and vertical rings on steel tank performance, focusing on sloshing behavior. The results of this study indicate that horizontal and vertical rings significantly influence the seismic performance of steel tanks, considering the effect of water sloshing, and a water level at half the tank’s height is optimal for withstanding seismic events. Also, it was found that if the height of the fluid is 58% of the tank height in all four cases, the highest stress will be created in the tank wall under the effect of turbulence. Examining the stress created at different heights showed that if the water level in the tank is more than one-sixth of the height of the tank, the average ratio of the highest stress level to the height of the water in the tank will be about 0.93.

Journal of structural design and construction practice.Vol. 31(3)
Instituto Tecnológico y de Estudios Superiores de Occidente (MX), Lakehead University (CA)
Clean water and sanitation
Openalex Percentile: Top 4%
Fluid Dynamics Simulations and Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.