Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples

Background: Schistosoma spp. are trematodes occurring in tropical endemic areas but can be imported to non-endemic regions as causes of travel-associated infections. In this study, two pan-trematode-specific real-time PCR assays were evaluated for their diagnostic sensitivity in detecting Schistosoma spp. DNA in diagnostic human samples. Methods: Two previously described pan-trematode-specific real-time PCR assays were comparatively assessed using diagnostic samples containing DNA of either the S. haematobium complex or the S. mansoni complex, as confirmed by Schistosoma species complex-specific real-time PCR. Results: Out of a total of 655 samples containing Schistosoma spp. DNA, positive signals in at least one of the two pan-trematode real-time PCR assays were recorded for 17 (2.6%) nucleic acid extractions. Although sensitivity was in the >90% range for stool samples, only a few individual blood plasma and serum samples, and none of the Schistosoma spp. DNA-containing tissue or urine samples, tested positive by pan-trematode PCR. The lower sensitivity of pan-trematode PCR compared with Schistosoma spp.-specific PCR was semi-quantitatively confirmed by higher cycle threshold (Ct) values in the former. When comparing samples with concordant versus discordant positive results for Schistosoma spp.-specific and pan-trematode PCR, Ct values of the Schistosoma spp.-specific PCR were lower in concordantly positive samples than in discordantly positive samples. Conclusions: While the assessed pan-trematode PCR assays showed insufficient sensitivity as screening tools for blood plasma, blood serum, tissue, and urine samples from individuals with suspected schistosomiasis, they were sufficiently sensitive when applied to stool samples, in which substantial amounts of target DNA, as indicated by low Ct values in the Schistosoma species complex-specific real-time PCR assays, can be expected. For screening for Schistosoma spp. DNA in sample materials other than stool, the use of highly sensitive target-specific PCR remains necessary.

Authors

Institutions

Publication Details

Journal
Infectious Disease Reports
Published
2026-03-27
DOI
https://doi.org/10.3390/idr18020027
Primary Topic
Parasites and Host Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples

Andreas Hahn, Kirsten Alexandra Eberhardt, Hagen Frickmann, Ralf Matthias Hagen et al.
Infectious Disease Reports
Parasites and Host Interactions
article

Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples

Andreas Hahn, Kirsten Alexandra Eberhardt, Hagen Frickmann, Ralf Matthias Hagen, Ulrike Loderstädt, Norbert Georg Schwarz
article en

Abstract

Background: Schistosoma spp. are trematodes occurring in tropical endemic areas but can be imported to non-endemic regions as causes of travel-associated infections. In this study, two pan-trematode-specific real-time PCR assays were evaluated for their diagnostic sensitivity in detecting Schistosoma spp. DNA in diagnostic human samples. Methods: Two previously described pan-trematode-specific real-time PCR assays were comparatively assessed using diagnostic samples containing DNA of either the S. haematobium complex or the S. mansoni complex, as confirmed by Schistosoma species complex-specific real-time PCR. Results: Out of a total of 655 samples containing Schistosoma spp. DNA, positive signals in at least one of the two pan-trematode real-time PCR assays were recorded for 17 (2.6%) nucleic acid extractions. Although sensitivity was in the >90% range for stool samples, only a few individual blood plasma and serum samples, and none of the Schistosoma spp. DNA-containing tissue or urine samples, tested positive by pan-trematode PCR. The lower sensitivity of pan-trematode PCR compared with Schistosoma spp.-specific PCR was semi-quantitatively confirmed by higher cycle threshold (Ct) values in the former. When comparing samples with concordant versus discordant positive results for Schistosoma spp.-specific and pan-trematode PCR, Ct values of the Schistosoma spp.-specific PCR were lower in concordantly positive samples than in discordantly positive samples. Conclusions: While the assessed pan-trematode PCR assays showed insufficient sensitivity as screening tools for blood plasma, blood serum, tissue, and urine samples from individuals with suspected schistosomiasis, they were sufficiently sensitive when applied to stool samples, in which substantial amounts of target DNA, as indicated by low Ct values in the Schistosoma species complex-specific real-time PCR assays, can be expected. For screening for Schistosoma spp. DNA in sample materials other than stool, the use of highly sensitive target-specific PCR remains necessary.

Infectious Disease ReportsVol. 18(2)
Boehringer Ingelheim (Germany) (DE), Düsseldorf University Hospital (DE), Bundeswehrkrankenhaus (DE), Universitätsmedizin Göttingen (DE), Bundeswehrzentralkrankenhaus Koblenz (DE), Heinrich Heine University Düsseldorf (DE), Bernhard Nocht Institute for Tropical Medicine (DE)
Openalex Percentile: Top 3%
Parasites and Host Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.