SURGICAL OUTCOMES OF A NOVEL NON-DIFFRACTIVE, EXTENDED DEPTH-OF-FOCUS INTRAOCULAR LENS - PRELIMINARY RESULTS FROM A PHASE 4 STUDY

• Extended depth of focus (EDOF) IOLs have been designed for those who want a continuous range of functional vision. • These IOLs focus incident light waves along an extended longitudinal plane rather than at discrete locations, preventing near and far views from overlapping. • Enova ADVANCEDTM (VSY BIOTECHNOLOGY) is a new generation extended depth of focus (EDOF) intraocular lens (IOL) that provides continuous vision at various distances. • The aim of this study is to uncover the outcomes of depth of focus, contrast sensitivity, and VA when using Enova ADVANCED TM (VSY BIOTECHNOLOGY) EDOF IOLs. Enova ADVANCED TM (VSY BIOTECHNOLOGY) is a new generation extended depth of focus (EDOF) intraocular lens (IOL) that provides continuous vision at various distances. The aim of this study was to present the first results of the EDOF IOL. This was a phase-4 retrospective cohort study. A total of 118 eyes of 59 patients data were reviewed. Mean aged of patients 66.62 ± 9.57 years (ranging, 32 - 84 years) with cataracts underwent bilateral implantation of Enova ADVANCED TM (VSY BIOTECHNOLOGY) (EDOF IOLs). The follow-up occurred on days 7 to 14, as well as at 2 months and 6 months post-treatment. The main goals included investigating monocular and binocular depth of focus at 6 months after surgery, uncorrected and best corrected distance, intermediate and near visual acuity (VA) up to 6 months following surgery, photopic and mesopic contrast sensitivity. A total of 59 patients with 118 eyes were included in the final analysis. Depth of focus with a monocular vision was observed across various threshold values, including 0.1 log MAR (+0.43 to -0.47 D), 0.2 log MAR (+0.73 to -0.9 D), and 0.3 log MAR (+1.05 to -1.72 D). Enova ADVANCED TM (VSY BIOTECHNOLOGY) had values of 0.1 log MAR (+0.52 to -0.58 D), 0.2 log MAR (+1.07 to -1.54 D), and 0.3 log MAR (+1.50 to -2.07 D) in terms of binocular depth of focus. Throughout all follow-up periods, there was a statistically significant improvement in distance, intermediate, and near VA when compared to the preoperative period (p <0.0001). All patients showed an improvement in refraction compared to the baseline measurement. Enova ADVANCED TM (VSY BIOTECHNOLOGY) patients exhibited high contrast sensitivity and the EDOF lens demonstrated good results without use of glasses. Mesopic values were relatively lower than photopic values (p<0.05). At 6 months, all IOLs were properly aligned without any instances of tilting. No general safety concerns were expressed in any patient. The Enova ADVANCED TM (VSY BIOTECHNOLOGY) EDOF IOLs demonstrated favorable vision outcomes, showing similar VA across various distances. Enova ADVANCED TM (VSY BIOTECHNOLOGY) provides a wide monocular depth of focus at 0.1 and 0.2 log MAR. The levels of spectacle independence and patient satisfaction were noticeably higher.

Authors

Institutions

Publication Details

Journal
Photodiagnosis and Photodynamic Therapy
Published
2026-03-01
DOI
https://doi.org/10.1016/j.pdpdt.2026.105446
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SURGICAL OUTCOMES OF A NOVEL NON-DIFFRACTIVE, EXTENDED DEPTH-OF-FOCUS INTRAOCULAR LENS - PRELIMINARY RESULTS FROM A PHASE 4 STUDY

Buğra Karasu, Enes Kesim, Ali Rıza Cenk Çelebi
Photodiagnosis and Photodynamic Therapy
Corneal surgery and disorders
article

SURGICAL OUTCOMES OF A NOVEL NON-DIFFRACTIVE, EXTENDED DEPTH-OF-FOCUS INTRAOCULAR LENS - PRELIMINARY RESULTS FROM A PHASE 4 STUDY

Buğra Karasu, Enes Kesim, Ali Rıza Cenk Çelebi
article en

Abstract

• Extended depth of focus (EDOF) IOLs have been designed for those who want a continuous range of functional vision. • These IOLs focus incident light waves along an extended longitudinal plane rather than at discrete locations, preventing near and far views from overlapping. • Enova ADVANCEDTM (VSY BIOTECHNOLOGY) is a new generation extended depth of focus (EDOF) intraocular lens (IOL) that provides continuous vision at various distances. • The aim of this study is to uncover the outcomes of depth of focus, contrast sensitivity, and VA when using Enova ADVANCED TM (VSY BIOTECHNOLOGY) EDOF IOLs. Enova ADVANCED TM (VSY BIOTECHNOLOGY) is a new generation extended depth of focus (EDOF) intraocular lens (IOL) that provides continuous vision at various distances. The aim of this study was to present the first results of the EDOF IOL. This was a phase-4 retrospective cohort study. A total of 118 eyes of 59 patients data were reviewed. Mean aged of patients 66.62 ± 9.57 years (ranging, 32 - 84 years) with cataracts underwent bilateral implantation of Enova ADVANCED TM (VSY BIOTECHNOLOGY) (EDOF IOLs). The follow-up occurred on days 7 to 14, as well as at 2 months and 6 months post-treatment. The main goals included investigating monocular and binocular depth of focus at 6 months after surgery, uncorrected and best corrected distance, intermediate and near visual acuity (VA) up to 6 months following surgery, photopic and mesopic contrast sensitivity. A total of 59 patients with 118 eyes were included in the final analysis. Depth of focus with a monocular vision was observed across various threshold values, including 0.1 log MAR (+0.43 to -0.47 D), 0.2 log MAR (+0.73 to -0.9 D), and 0.3 log MAR (+1.05 to -1.72 D). Enova ADVANCED TM (VSY BIOTECHNOLOGY) had values of 0.1 log MAR (+0.52 to -0.58 D), 0.2 log MAR (+1.07 to -1.54 D), and 0.3 log MAR (+1.50 to -2.07 D) in terms of binocular depth of focus. Throughout all follow-up periods, there was a statistically significant improvement in distance, intermediate, and near VA when compared to the preoperative period (p <0.0001). All patients showed an improvement in refraction compared to the baseline measurement. Enova ADVANCED TM (VSY BIOTECHNOLOGY) patients exhibited high contrast sensitivity and the EDOF lens demonstrated good results without use of glasses. Mesopic values were relatively lower than photopic values (p<0.05). At 6 months, all IOLs were properly aligned without any instances of tilting. No general safety concerns were expressed in any patient. The Enova ADVANCED TM (VSY BIOTECHNOLOGY) EDOF IOLs demonstrated favorable vision outcomes, showing similar VA across various distances. Enova ADVANCED TM (VSY BIOTECHNOLOGY) provides a wide monocular depth of focus at 0.1 and 0.2 log MAR. The levels of spectacle independence and patient satisfaction were noticeably higher.

Photodiagnosis and Photodynamic Therapy
Istinye University (TR), Kocaeli Üniversitesi (TR)
Gender equality
Openalex Percentile: Top 5%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.