DEVELOPMENT OF AN ELECTROCHEMICAL SENSOR FOR MORE RAPID HIF-1Α DETECTION AS AN ALTERNATIVE TO WESTERN BLOT ANALYSIS

Oxygen levels in the body/and organs significantly influence the regulation of metabolic reactions. Hypoxia, a decrease in oxygen levels, can potentially trigger various signals leading to serious health issues. This study aimed to develop an electrochemical immunosensor platform for rapidly and accurately detecting the hypoxia biomarker, HIF-1α protein. In this regard, screen-printed gold electrodes were modified using 11-mercaptoundecanoic acid and 3-mercapto-1-propanol (as a spacer) to generate functional carboxyl groups. Employing EDC-NHS chemistry facilitated the immobilization of HIF-1α antibodies, which were then utilized for the selective and specific recognition of their target. Electrochemical voltametric measurements were conducted using a potassium ferri/ferrocyanide redox couple in both hypoxia-cultured cell lysates and phosphate-buffered saline spiked with HIF-1α protein.In addition to electrochemical measurements, Western blotting (WB) was performed to compare findings with electrochemical results and to confirm the presence of HIF-1α in hypoxic cell lysates. While WB results only exhibited the qualitative presence of the respective antigen in lysates, significant signal decreases were observed in both Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) measurements due to specific antibody-target binding, emphasizing the electrochemical sensor’s performance for more rapid and quantitative protein detection. The low limit of detection (1.46 nM) suggests the potential of our proposed immunosensor platform for detecting HIF-1α protein within a clinically significant range, which is highly desired for point-of-care applications. This study is one of its kind in the literature to develop an electrochemical immunosensor platform for the rapid detection of HIF-1α. The sensor's ability to provide inexpensive, rapid, and quantitative measurements is a significant advancement for HIF-1 α detection.

Authors

Institutions

Publication Details

Journal
Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering
Published
2026-03-27
DOI
https://doi.org/10.18038/estubtda.1737583
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT OF AN ELECTROCHEMICAL SENSOR FOR MORE RAPID HIF-1Α DETECTION AS AN ALTERNATIVE TO WESTERN BLOT ANALYSIS

Araz Norouz Dizaji, Fatma DOĞAN GUZEL, Didem L. Kozaci, Kubra Kaya et al.
Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering
Electrochemical sensors and biosensors
article

DEVELOPMENT OF AN ELECTROCHEMICAL SENSOR FOR MORE RAPID HIF-1Α DETECTION AS AN ALTERNATIVE TO WESTERN BLOT ANALYSIS

Araz Norouz Dizaji, Fatma DOĞAN GUZEL, Didem L. Kozaci, Kubra Kaya, Ahmet Uçar
article en

Abstract

Oxygen levels in the body/and organs significantly influence the regulation of metabolic reactions. Hypoxia, a decrease in oxygen levels, can potentially trigger various signals leading to serious health issues. This study aimed to develop an electrochemical immunosensor platform for rapidly and accurately detecting the hypoxia biomarker, HIF-1α protein. In this regard, screen-printed gold electrodes were modified using 11-mercaptoundecanoic acid and 3-mercapto-1-propanol (as a spacer) to generate functional carboxyl groups. Employing EDC-NHS chemistry facilitated the immobilization of HIF-1α antibodies, which were then utilized for the selective and specific recognition of their target. Electrochemical voltametric measurements were conducted using a potassium ferri/ferrocyanide redox couple in both hypoxia-cultured cell lysates and phosphate-buffered saline spiked with HIF-1α protein.In addition to electrochemical measurements, Western blotting (WB) was performed to compare findings with electrochemical results and to confirm the presence of HIF-1α in hypoxic cell lysates. While WB results only exhibited the qualitative presence of the respective antigen in lysates, significant signal decreases were observed in both Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) measurements due to specific antibody-target binding, emphasizing the electrochemical sensor’s performance for more rapid and quantitative protein detection. The low limit of detection (1.46 nM) suggests the potential of our proposed immunosensor platform for detecting HIF-1α protein within a clinically significant range, which is highly desired for point-of-care applications. This study is one of its kind in the literature to develop an electrochemical immunosensor platform for the rapid detection of HIF-1α. The sensor's ability to provide inexpensive, rapid, and quantitative measurements is a significant advancement for HIF-1 α detection.

Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and EngineeringVol. 27(1)
Ankara University (TR), Ankara Yıldırım Beyazıt University (TR)
Openalex Percentile: Top 5%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.