Clinically-Ready Label-Flip Detection for Medical AI

Medical AI pipelines face integrity risks from label flipping—mislabeling that harms thresholds, calibration, and parity. Because anomalies are rare, evolving, and often mislabeled, a purely supervised detector tends to miss new problems and flood reviewers with false alarms; a triage loop—rank strong model-vs-label disagreements, review a small top slice, fix, retrain—keeps effort low and results trustworthy. We present a lightweight procedure: basic plausibility/duplicate checks; leakage-safe K-fold cross-fitting; calibration; and Confident Learning to derive per-example flip scores (and the confident joint). High-scoring cases receive budgeted chart-review; we then selectively relabel or reweight, retrain, and recalibrate. We evaluate flip-ranking (PR-AUC, precision@k, TPR@low-FPR) and downstream AUROC/PR-AUC, ECE/Brier, and parity deltas. A HiRID ICU case demonstrates integrity and calibration gains with limited review effort.

Authors

Institutions

Publication Details

Journal
OJS
Published
2026-03-27
DOI
https://doi.org/10.60643/urai.v2025p13
Primary Topic
Adversarial Robustness in Machine Learning
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinically-Ready Label-Flip Detection for Medical AI

Daniel Schönle, Christoph Reich
OJS
Adversarial Robustness in Machine Learning
article

Clinically-Ready Label-Flip Detection for Medical AI

Daniel Schönle, Christoph Reich
article en

Abstract

Medical AI pipelines face integrity risks from label flipping—mislabeling that harms thresholds, calibration, and parity. Because anomalies are rare, evolving, and often mislabeled, a purely supervised detector tends to miss new problems and flood reviewers with false alarms; a triage loop—rank strong model-vs-label disagreements, review a small top slice, fix, retrain—keeps effort low and results trustworthy. We present a lightweight procedure: basic plausibility/duplicate checks; leakage-safe K-fold cross-fitting; calibration; and Confident Learning to derive per-example flip scores (and the confident joint). High-scoring cases receive budgeted chart-review; we then selectively relabel or reweight, retrain, and recalibrate. We evaluate flip-ranking (PR-AUC, precision@k, TPR@low-FPR) and downstream AUROC/PR-AUC, ECE/Brier, and parity deltas. A HiRID ICU case demonstrates integrity and calibration gains with limited review effort.

OJS
Furtwangen University (DE)
Openalex Percentile: Top 6%
Adversarial Robustness in Machine Learning
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.