Management of No-Reflow With Intracoronary Thrombolysis: A Case Report

No-reflow is a recurring phenomenon during coronary angioplasty that consists of the failure to reestablish blood flow after clearing an occluded coronary artery. Several treatments have been proposed for the management of no-reflow, including intracoronary thrombolysis, which has emerged in recent years as one of the means of managing this phenomenon. We report the case of a 68-year-old female patient with a high cardiovascular risk, admitted for the management of non-ST-elevation acute coronary syndrome, who presented a no-reflow phenomenon after angioplasty of the right coronary artery. After the failure of the various means available to reopen the artery, a 30 mg dose of tenecteplase was administered intracoronary with restoration of Thrombolysis in Myocardial Infarction III flow in the angiographic control and good clinical and rhythmic evolution. Fibrinolytic agents remain an effective means in the treatment of acute coronary syndromes with ST-segment elevation. Its use in intracoronary therapy has demonstrated its benefit in restoring flow and improving microcirculation while maintaining a satisfactory safety profile. The use of these agents in the treatment of no-reflow remains an alternative to the usual treatment, such as adenosine and verapamil, and mechanical means, such as thrombo-aspiration, allowing dissolution of the thrombus and reestablishment of the flow. The management of no-reflow phenomena remains difficult, given the varied pathophysiology of this phenomenon and the therapeutic arsenal available for its management. However, intracoronary thrombolysis for the management of no-reflow remains an attractive and interesting alternative with results that remain acceptable, but which need to be approved by studies on larger samples with more details on the dose and the administration methodology.

Authors

Publication Details

Journal
Cureus
Published
2026-03-27
DOI
https://doi.org/10.7759/cureus.105951
Primary Topic
Acute Myocardial Infarction Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Management of No-Reflow With Intracoronary Thrombolysis: A Case Report

Youssef Fihri, Driss Britel, Aatif Benyass, Zouhair Lakhal et al.
Cureus
Acute Myocardial Infarction Research
article

Management of No-Reflow With Intracoronary Thrombolysis: A Case Report

Youssef Fihri, Driss Britel, Aatif Benyass, Zouhair Lakhal, Fatima Ezahra Elktaibi
article en

Abstract

No-reflow is a recurring phenomenon during coronary angioplasty that consists of the failure to reestablish blood flow after clearing an occluded coronary artery. Several treatments have been proposed for the management of no-reflow, including intracoronary thrombolysis, which has emerged in recent years as one of the means of managing this phenomenon. We report the case of a 68-year-old female patient with a high cardiovascular risk, admitted for the management of non-ST-elevation acute coronary syndrome, who presented a no-reflow phenomenon after angioplasty of the right coronary artery. After the failure of the various means available to reopen the artery, a 30 mg dose of tenecteplase was administered intracoronary with restoration of Thrombolysis in Myocardial Infarction III flow in the angiographic control and good clinical and rhythmic evolution. Fibrinolytic agents remain an effective means in the treatment of acute coronary syndromes with ST-segment elevation. Its use in intracoronary therapy has demonstrated its benefit in restoring flow and improving microcirculation while maintaining a satisfactory safety profile. The use of these agents in the treatment of no-reflow remains an alternative to the usual treatment, such as adenosine and verapamil, and mechanical means, such as thrombo-aspiration, allowing dissolution of the thrombus and reestablishment of the flow. The management of no-reflow phenomena remains difficult, given the varied pathophysiology of this phenomenon and the therapeutic arsenal available for its management. However, intracoronary thrombolysis for the management of no-reflow remains an attractive and interesting alternative with results that remain acceptable, but which need to be approved by studies on larger samples with more details on the dose and the administration methodology.

Cureus
Good health and well-being
Openalex Percentile: Top 8%
Acute Myocardial Infarction Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.