Finite Element Analysis for the Load-Bearing Femur and Tibia in the Human Knee Using an In Vivo HR-pQCT Protocol

High-resolution peripheral quantitative CT (HR-pQCT) combined with microfinite element (μFE) analysis enables noninvasive assessment of bone mechanics. While widely used at the distal radius and tibia, knee modeling is challenging due to complex geometry, large model sizes, and the need for physiologically relevant boundary conditions. Standardization and reproducibility are critical for interpreting mechanical predictions. HR-pQCT images were collected from one participant with recent ACL injury for boundary condition testing and 28 healthy volunteers for reproducibility. Patient-specific μFE models incorporated anatomically shaped or rectangular simulated-PMMA support layers with variable stiffness (1500-3000MPa) and extrusion lengths (1-7mm). Sensitivity analyses quantified the influence of layer geometry, stiffness, and length on strain energy density (SED). Reproducibility of repeated tibial scans was assessed using RMS%CV and ICC. μFE knee models contained hundreds of millions of degrees of freedom, with solution times of 3.6-16.4h for anatomically shaped layers and 4.1-20.1h for rectangular layers (32 cores). Support layer stiffness had the greatest effect on tibial SED, whereas geometry and length had minimal influence. Reproducibility across tibial scans ranged from 5.5-18.4% RMS %CV, with ICCs of 0.72-0.94; peri-articular trabecular regions 5-7.5mm below the articular surface were most stable. Standardized HR-pQCT-based μFE knee modeling is essential for reproducibility. An anatomically shaped, 3mm extruded PMMA-like support layer with ~2500MPa stiffness provides stable, computationally efficient load distribution and will facilitate comparability in future longitudinal knee studies.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanical Engineering
Published
2026-03-27
DOI
https://doi.org/10.1115/1.4071535
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element Analysis for the Load-Bearing Femur and Tibia in the Human Knee Using an In Vivo HR-pQCT Protocol

C. Stirling, Steven K. Boyd
Journal of Biomechanical Engineering
Total Knee Arthroplasty Outcomes
article

Finite Element Analysis for the Load-Bearing Femur and Tibia in the Human Knee Using an In Vivo HR-pQCT Protocol

C. Stirling, Steven K. Boyd
article en

Abstract

High-resolution peripheral quantitative CT (HR-pQCT) combined with microfinite element (μFE) analysis enables noninvasive assessment of bone mechanics. While widely used at the distal radius and tibia, knee modeling is challenging due to complex geometry, large model sizes, and the need for physiologically relevant boundary conditions. Standardization and reproducibility are critical for interpreting mechanical predictions. HR-pQCT images were collected from one participant with recent ACL injury for boundary condition testing and 28 healthy volunteers for reproducibility. Patient-specific μFE models incorporated anatomically shaped or rectangular simulated-PMMA support layers with variable stiffness (1500-3000MPa) and extrusion lengths (1-7mm). Sensitivity analyses quantified the influence of layer geometry, stiffness, and length on strain energy density (SED). Reproducibility of repeated tibial scans was assessed using RMS%CV and ICC. μFE knee models contained hundreds of millions of degrees of freedom, with solution times of 3.6-16.4h for anatomically shaped layers and 4.1-20.1h for rectangular layers (32 cores). Support layer stiffness had the greatest effect on tibial SED, whereas geometry and length had minimal influence. Reproducibility across tibial scans ranged from 5.5-18.4% RMS %CV, with ICCs of 0.72-0.94; peri-articular trabecular regions 5-7.5mm below the articular surface were most stable. Standardized HR-pQCT-based μFE knee modeling is essential for reproducibility. An anatomically shaped, 3mm extruded PMMA-like support layer with ~2500MPa stiffness provides stable, computationally efficient load distribution and will facilitate comparability in future longitudinal knee studies.

Journal of Biomechanical Engineering
University of Calgary (CA), Alberta Bone and Joint Health Institute (CA)
Openalex Percentile: Top 4%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.