Assessing Respiratory Motion Stability of Novel 18F-Fluorodeoxyglucose Positron Emission Tomography-Derived Morphological Features

Background/Objectives: Novel hotspot displacement radiomic features (normalized hotspot-to-centroid distance [NHOC]/normalized hotspot-to-perimeter distance [NHOP]) are robust against image resampling and spatial resolution variations. However, their reproducibility under respiratory motion remains unvalidated. This study aimed to evaluate the reproducibility, reliability, and survival prognostic value of NHOC/NHOP features in thoracic 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images with and without respiratory motion correction and to determine whether these features maintain stability and predictive performance for overall survival (OS) compared with respiratory-stable reference features. Methods: We analyzed 138 patients (203 lesions) who underwent 18F-FDG PET/CT with and without data-driven respiratory gating. Reproducibility and reliability were assessed using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC), respectively. OS prediction was evaluated using Cox regression and concordance index (c-index) analyses. Results: Except for NHOCmax and NHOPpeak, which showed ICC values of 0.782 and 0.93, respectively, the novel morphological features generally exhibited poor reproducibility and moderate reliability (CoV > 20% and ICC < 0.75). In contrast, reference features (entropy-based and sphericity) demonstrated excellent robustness. Motion-corrected NHOCmax showed significant OS prediction for both spatially resampled and non-resampled images. No significant differences in c-indices were observed between motion-corrected and non-corrected features. Conclusions: The marked sensitivity of novel hotspot-displacement features to respiratory motion substantially limits their clinical applicability in thoracic disease. To ensure reproducibility and generalizability in future research, prioritizing inherently robust radiomic parameters, such as entropy-based features, is strongly recommended.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-03-26
DOI
https://doi.org/10.3390/diagnostics16070994
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Respiratory Motion Stability of Novel 18F-Fluorodeoxyglucose Positron Emission Tomography-Derived Morphological Features

Chih‐Bin Lin, Yu-Hung Chen, Shu-Hsin Liu, Kun-Han Lue et al.
Diagnostics
Radiomics and Machine Learning in Medical Imaging
article

Assessing Respiratory Motion Stability of Novel 18F-Fluorodeoxyglucose Positron Emission Tomography-Derived Morphological Features

Chih‐Bin Lin, Yu-Hung Chen, Shu-Hsin Liu, Kun-Han Lue, Sze Ian Tan, Sung-Chao Chu
article en

Abstract

Background/Objectives: Novel hotspot displacement radiomic features (normalized hotspot-to-centroid distance [NHOC]/normalized hotspot-to-perimeter distance [NHOP]) are robust against image resampling and spatial resolution variations. However, their reproducibility under respiratory motion remains unvalidated. This study aimed to evaluate the reproducibility, reliability, and survival prognostic value of NHOC/NHOP features in thoracic 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images with and without respiratory motion correction and to determine whether these features maintain stability and predictive performance for overall survival (OS) compared with respiratory-stable reference features. Methods: We analyzed 138 patients (203 lesions) who underwent 18F-FDG PET/CT with and without data-driven respiratory gating. Reproducibility and reliability were assessed using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC), respectively. OS prediction was evaluated using Cox regression and concordance index (c-index) analyses. Results: Except for NHOCmax and NHOPpeak, which showed ICC values of 0.782 and 0.93, respectively, the novel morphological features generally exhibited poor reproducibility and moderate reliability (CoV > 20% and ICC < 0.75). In contrast, reference features (entropy-based and sphericity) demonstrated excellent robustness. Motion-corrected NHOCmax showed significant OS prediction for both spatially resampled and non-resampled images. No significant differences in c-indices were observed between motion-corrected and non-corrected features. Conclusions: The marked sensitivity of novel hotspot-displacement features to respiratory motion substantially limits their clinical applicability in thoracic disease. To ensure reproducibility and generalizability in future research, prioritizing inherently robust radiomic parameters, such as entropy-based features, is strongly recommended.

DiagnosticsVol. 16(7)
Tzu Chi University (TW), Tzu Chi Foundation (TW), Hualien Tzu Chi Medical Center (TW)
Openalex Percentile: Top 5%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.