Patient-Specific Finite Element Analysis of Tibialis Anterior Tendon Insertion Variability and Its Impact on First Ray Biomechanics

Background: Hallux valgus (HV) is a complex forefoot deformity influenced by interactions between osseous alignment, ligamentous restraint, and muscle–tendon forces. While the biomechanical role of ligament laxity and bone geometry has been extensively investigated, the contribution of tibialis anterior (TA) tendon insertion variability to medial column mechanics remains insufficiently understood. Materials and Methods: A patient-specific finite element model of the foot was developed from high-resolution computed tomography data. Five anatomically documented TA distal insertion configurations were modeled, representing different distributions of attachment to the medial cuneiform and first metatarsal base. All simulations were performed under identical boundary and loading conditions representative of the stance phase of gait. Global (full-foot) and local (first bone and first metatarsal) mechanical responses were quantified using total deformation, equivalent von Mises stress, and strain distributions. Results: Marked differences in mechanical behavior were observed across TA insertion types. The metatarsal-dominant configuration (Type 3) demonstrated the highest global and local deformation values (global deformation: 1.0928 mm; first bone deformation: 1.0928 mm) and elevated strain distributions, whereas the medial-dominant configuration (Type 2) showed minimal deformation (global: 0.0727 mm; first bone: 0.0350 mm) but the highest global equivalent von Mises stress (5.7698 MPa). The single-band insertion to the medial cuneiform (Type 5) produced the greatest localized stress in the first bone region (3.8634 MPa). Representative strain maps revealed distinct spatial redistribution patterns within the medial column associated with TA insertion geometry. Conclusions: This patient-specific finite element analysis indicated that distal TA insertion variability alone can substantially modify deformation, stress, and strain patterns within the medial column. These findings suggested that TA insertion anatomy may act as a biomechanical modulator of first-ray mechanics and should be considered in future studies investigating hallux valgus pathomechanics and personalized treatment strategies.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-03-27
DOI
https://doi.org/10.3390/bioengineering13040389
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient-Specific Finite Element Analysis of Tibialis Anterior Tendon Insertion Variability and Its Impact on First Ray Biomechanics

İrfan Kaymaz, Recep Taşkin, Fatih Ugur, Osman Yazici
Bioengineering
Foot and Ankle Surgery
article

Patient-Specific Finite Element Analysis of Tibialis Anterior Tendon Insertion Variability and Its Impact on First Ray Biomechanics

İrfan Kaymaz, Recep Taşkin, Fatih Ugur, Osman Yazici
article en

Abstract

Background: Hallux valgus (HV) is a complex forefoot deformity influenced by interactions between osseous alignment, ligamentous restraint, and muscle–tendon forces. While the biomechanical role of ligament laxity and bone geometry has been extensively investigated, the contribution of tibialis anterior (TA) tendon insertion variability to medial column mechanics remains insufficiently understood. Materials and Methods: A patient-specific finite element model of the foot was developed from high-resolution computed tomography data. Five anatomically documented TA distal insertion configurations were modeled, representing different distributions of attachment to the medial cuneiform and first metatarsal base. All simulations were performed under identical boundary and loading conditions representative of the stance phase of gait. Global (full-foot) and local (first bone and first metatarsal) mechanical responses were quantified using total deformation, equivalent von Mises stress, and strain distributions. Results: Marked differences in mechanical behavior were observed across TA insertion types. The metatarsal-dominant configuration (Type 3) demonstrated the highest global and local deformation values (global deformation: 1.0928 mm; first bone deformation: 1.0928 mm) and elevated strain distributions, whereas the medial-dominant configuration (Type 2) showed minimal deformation (global: 0.0727 mm; first bone: 0.0350 mm) but the highest global equivalent von Mises stress (5.7698 MPa). The single-band insertion to the medial cuneiform (Type 5) produced the greatest localized stress in the first bone region (3.8634 MPa). Representative strain maps revealed distinct spatial redistribution patterns within the medial column associated with TA insertion geometry. Conclusions: This patient-specific finite element analysis indicated that distal TA insertion variability alone can substantially modify deformation, stress, and strain patterns within the medial column. These findings suggested that TA insertion anatomy may act as a biomechanical modulator of first-ray mechanics and should be considered in future studies investigating hallux valgus pathomechanics and personalized treatment strategies.

BioengineeringVol. 13(4)
Erzurum Technical University (TR), Kastamonu University (TR)
Openalex Percentile: Top 5%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.