SRS194 - Machine perfusion modulates cold preservation injury in kidney transplantation: IDEAL stage 4 UNOS population cohort study

Abstract Background Hypothermic machine perfusion (HMP) has surged in popularity to ameliorate renal IRI. Continuous-HMP (cHMP) has shown clear benefits over SCS, whereas randomised trials on short-duration end-ischemic-HMP (eiHMP) have shown no benefit. In this study, we aimed to assess the association of different HMP timings with outcome, and whether HMP modulates the negative impact of increasing cold preservation-time Methods This cohort study used UNOS data (2010–2024). Multivariable regression models, with interaction terms, were used to analyse associations, and restricted cubic spline modelling accounted non-linear relationships Results All HMP timings, versus SCS, were significantly associated with reduced DGF (cHMP:aOR = 0.484, 95%c.i. = 0.467–0.501; eiHMP:aOR = 0.459, 95%c.i. = 0.435–0.485) and shorter hospital LOS (n = 137 835). Non-linear interaction analyses revealed HMP mitigated the negative effect of additional hours of cold preservation-time compared with SCS (interaction P < 0.001). cHMP showed benefit across all cold preservation-times, whereas eiHMP was beneficial only in the setting of prolonged cold preservation-time. The effect of HMP varied by donor type, with greater benefit observed in DCD grafts beyond benefits already seen in DBD grafts. Additionally, the protective effect of eiHMP appeared at shorter cold preservation-times in DCD compared with DBD grafts. HMP was also associated with significantly improved 5-year graft and patient survival. Conclusions HMP reduced the negative effects of additional hours of cold preservation-time. Therefore, the treatment effect of HMP was not fixed and increased with longer cold preservation-time. eiHMP improved outcome only at prolonged cold preservation-time. The association of HMP with improved 5-year graft survival and mortality provides real-world IDEAL stage 4 evidence.

Authors

Institutions

Publication Details

Journal
British journal of surgery
Published
2026-03-01
DOI
https://doi.org/10.1093/bjs/znag018.182
Primary Topic
Organ Transplantation Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SRS194 - Machine perfusion modulates cold preservation injury in kidney transplantation: IDEAL stage 4 UNOS population cohort study

Dharesh Raj Amarnath, Dorry Segev, Allan Massie, Colin Wilson et al.
British journal of surgery
Organ Transplantation Techniques and Outcomes
article

SRS194 - Machine perfusion modulates cold preservation injury in kidney transplantation: IDEAL stage 4 UNOS population cohort study

Dharesh Raj Amarnath, Dorry Segev, Allan Massie, Colin Wilson, Ina Jochmans, Samuel Tingle, Georgios Kourounis
article en

Abstract

Abstract Background Hypothermic machine perfusion (HMP) has surged in popularity to ameliorate renal IRI. Continuous-HMP (cHMP) has shown clear benefits over SCS, whereas randomised trials on short-duration end-ischemic-HMP (eiHMP) have shown no benefit. In this study, we aimed to assess the association of different HMP timings with outcome, and whether HMP modulates the negative impact of increasing cold preservation-time Methods This cohort study used UNOS data (2010–2024). Multivariable regression models, with interaction terms, were used to analyse associations, and restricted cubic spline modelling accounted non-linear relationships Results All HMP timings, versus SCS, were significantly associated with reduced DGF (cHMP:aOR = 0.484, 95%c.i. = 0.467–0.501; eiHMP:aOR = 0.459, 95%c.i. = 0.435–0.485) and shorter hospital LOS (n = 137 835). Non-linear interaction analyses revealed HMP mitigated the negative effect of additional hours of cold preservation-time compared with SCS (interaction P < 0.001). cHMP showed benefit across all cold preservation-times, whereas eiHMP was beneficial only in the setting of prolonged cold preservation-time. The effect of HMP varied by donor type, with greater benefit observed in DCD grafts beyond benefits already seen in DBD grafts. Additionally, the protective effect of eiHMP appeared at shorter cold preservation-times in DCD compared with DBD grafts. HMP was also associated with significantly improved 5-year graft and patient survival. Conclusions HMP reduced the negative effects of additional hours of cold preservation-time. Therefore, the treatment effect of HMP was not fixed and increased with longer cold preservation-time. eiHMP improved outcome only at prolonged cold preservation-time. The association of HMP with improved 5-year graft survival and mortality provides real-world IDEAL stage 4 evidence.

British journal of surgeryVol. 113(Supplement_2)
Freeman Hospital (GB), NYU Langone Health (US), Newcastle University (GB), KU Leuven (BE)
Life in Land
Openalex Percentile: Top 5%
Organ Transplantation Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.