Bond Strength of Staggered and Nonstaggered GFRP Lap-Spliced Bars in Normal and Fiber-Reinforced Concrete Beams

This study evaluated the performance of glass fiber–reinforced polymer (GFRP) lap-spliced bars in concrete beams, focusing on the effects of splice configuration and the use of fiber-reinforced concrete using macrosynthetic fibers through large-scale testing of six beam specimens. The investigation compared nonstaggered (100% of bars spliced at the same section) and fully staggered (50% of bars spliced with a center-to-center distance of 1.3ls) splices, using No. 5 sand-coated GFRP bars with a splice length of 38db. Experimental results reveal that, while precracking stiffness was similar across all beams, fully staggered splices enhanced load-carrying capacity by 6.4% and promoted a ductile, multistage failure mechanism, retaining approximately 85% of peak strength postinitial splice failure. The inclusion of synthetic macrofibers at 1.8 and 2.7 kg/m3 dosages increased postcracking stiffness by up to 8% and 18% for nonstaggered and staggered configurations, respectively, and boosted ultimate load capacity by 7.9% and 16.8%. Crack width analysis showed that staggered splices and fiber reinforcement significantly reduced crack propagation, with fully staggered fiber-reinforced beams achieving a 1.0-mm crack width at higher loads (up to 108.5 kN) compared to nonstaggered beams (up to 99.8 kN). Bond strength was enhanced by 5.6%–14.6% in fully staggered and fiber-reinforced beams due to improved stress distribution and crack-bridging effects. Comparisons with the existing design codes revealed limitations in capturing fiber and staggering effects, prompting the development of a modified bond strength equation that incorporates splice staggering and fiber content, achieving the average test-to-prediction ratios of 1.03. These findings offer critical insights for optimizing GFRP-reinforced concrete structures and refining bond strength provisions in design guidelines.

Authors

Institutions

Publication Details

Journal
Journal of Composites for Construction
Published
2026-03-27
DOI
https://doi.org/10.1061/jccof2.cceng-5391
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bond Strength of Staggered and Nonstaggered GFRP Lap-Spliced Bars in Normal and Fiber-Reinforced Concrete Beams

Adel ElSafty, Abolfazl Eslami, Ahmed Sabry Farghaly, Brahim Benmokrane et al.
Journal of Composites for Construction
Structural Behavior of Reinforced Concrete
article

Bond Strength of Staggered and Nonstaggered GFRP Lap-Spliced Bars in Normal and Fiber-Reinforced Concrete Beams

Adel ElSafty, Abolfazl Eslami, Ahmed Sabry Farghaly, Brahim Benmokrane, Seyed Arman Hosseini
article en

Abstract

This study evaluated the performance of glass fiber–reinforced polymer (GFRP) lap-spliced bars in concrete beams, focusing on the effects of splice configuration and the use of fiber-reinforced concrete using macrosynthetic fibers through large-scale testing of six beam specimens. The investigation compared nonstaggered (100% of bars spliced at the same section) and fully staggered (50% of bars spliced with a center-to-center distance of 1.3ls) splices, using No. 5 sand-coated GFRP bars with a splice length of 38db. Experimental results reveal that, while precracking stiffness was similar across all beams, fully staggered splices enhanced load-carrying capacity by 6.4% and promoted a ductile, multistage failure mechanism, retaining approximately 85% of peak strength postinitial splice failure. The inclusion of synthetic macrofibers at 1.8 and 2.7 kg/m3 dosages increased postcracking stiffness by up to 8% and 18% for nonstaggered and staggered configurations, respectively, and boosted ultimate load capacity by 7.9% and 16.8%. Crack width analysis showed that staggered splices and fiber reinforcement significantly reduced crack propagation, with fully staggered fiber-reinforced beams achieving a 1.0-mm crack width at higher loads (up to 108.5 kN) compared to nonstaggered beams (up to 99.8 kN). Bond strength was enhanced by 5.6%–14.6% in fully staggered and fiber-reinforced beams due to improved stress distribution and crack-bridging effects. Comparisons with the existing design codes revealed limitations in capturing fiber and staggering effects, prompting the development of a modified bond strength equation that incorporates splice staggering and fiber content, achieving the average test-to-prediction ratios of 1.03. These findings offer critical insights for optimizing GFRP-reinforced concrete structures and refining bond strength provisions in design guidelines.

Journal of Composites for ConstructionVol. 30(3)
University of North Florida (US), Université de Sherbrooke (CA)
Sustainable cities and communities
Openalex Percentile: Top 6%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.