Biodegradation of Tissue Separation Spacer Implant

The biodegradation of inflated spacers made of PLCL 70:30 (poly(L‐lactide ‐ co‐ε‐caprolactone)) is investigated. This spacer is intended to temporarily position the anterior rectal wall away from the prostate during radiotherapy of prostate cancer. When inflated with phosphate buffer solution, this spacer implant creates space in the anterior rectum, thereby reducing radiation‐induced damage. The mechanical stability of such inflated biodegradable systems over time is highly compromised, and their stability is uncertain due to continuous hydrolysis of the polymer material and imbalance with the muscular pressure that constantly acts on the inflated implant. Herein, detailed in vitro and in vivo degradation data of the inflated spacer are reported and correlated with its stability under a constant mechanical pressure that impersonates the pressure created by the anterior rectum on the spacers. The mechanical and physicochemical test results have a direct correlation with the degradation profile of the PLCL material. Mechanical testing demonstrates spacer inflation for at least 13 weeks.

Authors

Institutions

Publication Details

Journal
Israel Journal of Chemistry
Published
2026-03-01
DOI
https://doi.org/10.1002/ijch.70005
Primary Topic
biodegradable polymer synthesis and properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biodegradation of Tissue Separation Spacer Implant

Abraham Jacob Domb, Abraham Nyska, Awanish Kumar, Yuval Ramot et al.
Israel Journal of Chemistry
biodegradable polymer synthesis and properties
article

Biodegradation of Tissue Separation Spacer Implant

Abraham Jacob Domb, Abraham Nyska, Awanish Kumar, Yuval Ramot, Muhammad Abd El‐haq
article en

Abstract

The biodegradation of inflated spacers made of PLCL 70:30 (poly(L‐lactide ‐ co‐ε‐caprolactone)) is investigated. This spacer is intended to temporarily position the anterior rectal wall away from the prostate during radiotherapy of prostate cancer. When inflated with phosphate buffer solution, this spacer implant creates space in the anterior rectum, thereby reducing radiation‐induced damage. The mechanical stability of such inflated biodegradable systems over time is highly compromised, and their stability is uncertain due to continuous hydrolysis of the polymer material and imbalance with the muscular pressure that constantly acts on the inflated implant. Herein, detailed in vitro and in vivo degradation data of the inflated spacer are reported and correlated with its stability under a constant mechanical pressure that impersonates the pressure created by the anterior rectum on the spacers. The mechanical and physicochemical test results have a direct correlation with the degradation profile of the PLCL material. Mechanical testing demonstrates spacer inflation for at least 13 weeks.

Israel Journal of ChemistryVol. 66(2)
Tel Aviv University (IL), Jerusalem College of Technology (IL), Hebrew University of Jerusalem (IL), Hadassah Medical Center (IL)
Openalex Percentile: Top 5%
biodegradable polymer synthesis and properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Biodegradation of Tissue Separation Spacer Implant — Abraham Jacob Domb, Abraham Nyska, et al. · Israel Journal of Chemistry (2026) | TGRS Research Map | TGRS