SRS138 - Crossed cannulated screws for phalangeal fractures: a novel fixation technique

Abstract Introduction Unstable phalangeal fractures require fixation that balances stability with early mobilisation. K-wires, though common, provide only relative stability, necessitate immobilisation, and are linked to infection and stiffness. Cannulated screws offer improved outcomes, yet standard configurations may lack rotational control and optimal load distribution. We present the first UK case series of cross-configuration headless cannulated screws, designed to deliver absolute stability, enhance biomechanics, and enable early recovery. Methods Ten adults with unstable, displaced proximal phalanx fractures were treated using 1.3–1.7 mm headless cannulated screws in a novel cross-configuration. Inclusion criteria were closed fractures requiring fixation. A dorsal or lateral approach was chosen per fracture site. Temporary K-wires secured reduction and guided screw trajectories before removal. All cases were performed under tourniquet. Immediate mobilisation and hand therapy were encouraged. Outcomes included range of motion (ROM), pain, return to activities, compliance, and complications. Results Ten patients (6 male, 4 female; mean age 42.8 ± 17.6 years) underwent fixation for transverse P1 fractures of the non-dominant hand. Mean time from injury to surgery was 14.0 ± 12.4 days. At 6 weeks, mean TAM was 205° (AROM 215°), with a mean PIP lag of 10°. Patients achieved early functional recovery, regaining dexterity for typing, grip, and light daily activities. Pain was minimal and did not restrict rehabilitation. Mild stiffness and occasional scissoring were observed but did not limit overall outcome. Conclusions Cross-configuration screw fixation provides stable outcomes, enabling early mobilisation, primary healing, and low complications. These findings suggest advantages over traditional fixation.

Authors

Institutions

Publication Details

Journal
British journal of surgery
Published
2026-03-01
DOI
https://doi.org/10.1093/bjs/znag018.134
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SRS138 - Crossed cannulated screws for phalangeal fractures: a novel fixation technique

David Zargaran, Jonathan Simmons, Fatima Braimah
British journal of surgery
Orthopedic Surgery and Rehabilitation
article

SRS138 - Crossed cannulated screws for phalangeal fractures: a novel fixation technique

David Zargaran, Jonathan Simmons, Fatima Braimah
article en

Abstract

Abstract Introduction Unstable phalangeal fractures require fixation that balances stability with early mobilisation. K-wires, though common, provide only relative stability, necessitate immobilisation, and are linked to infection and stiffness. Cannulated screws offer improved outcomes, yet standard configurations may lack rotational control and optimal load distribution. We present the first UK case series of cross-configuration headless cannulated screws, designed to deliver absolute stability, enhance biomechanics, and enable early recovery. Methods Ten adults with unstable, displaced proximal phalanx fractures were treated using 1.3–1.7 mm headless cannulated screws in a novel cross-configuration. Inclusion criteria were closed fractures requiring fixation. A dorsal or lateral approach was chosen per fracture site. Temporary K-wires secured reduction and guided screw trajectories before removal. All cases were performed under tourniquet. Immediate mobilisation and hand therapy were encouraged. Outcomes included range of motion (ROM), pain, return to activities, compliance, and complications. Results Ten patients (6 male, 4 female; mean age 42.8 ± 17.6 years) underwent fixation for transverse P1 fractures of the non-dominant hand. Mean time from injury to surgery was 14.0 ± 12.4 days. At 6 weeks, mean TAM was 205° (AROM 215°), with a mean PIP lag of 10°. Patients achieved early functional recovery, regaining dexterity for typing, grip, and light daily activities. Pain was minimal and did not restrict rehabilitation. Mild stiffness and occasional scissoring were observed but did not limit overall outcome. Conclusions Cross-configuration screw fixation provides stable outcomes, enabling early mobilisation, primary healing, and low complications. These findings suggest advantages over traditional fixation.

British journal of surgeryVol. 113(Supplement_2)
Imperial College Healthcare NHS Trust (GB)
Openalex Percentile: Top 5%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

SRS138 - Crossed cannulated screws for phalangeal fractures: a novel fixation technique — David Zargaran, Jonathan Simmons, et al. · British journal of surgery (2026) | TGRS Research Map | TGRS