Anti‐Biofilm Properties of Polyurethane Biomaterials Tethered With Small Molecules via Polyethylene Glycol Linker

Biofilm-associated microbial infection is one of the main complications for long-term use of biomaterials in implantable medical devices. Bacterial intracellular nucleotide second messenger signaling is widely recognized to be involved in biofilm formation and assists bacteria in monitoring and responding appropriately to changing environments. Interference with the nucleotide signaling mechanisms by small molecules to interrupt biofilm formation provides a novel way to control microbial infection on biomaterial surfaces. This study reports an approach to tether small molecule derivatives of 4-arylazo-3,5-diamino-1 H-pyrazole (termed as SP02 and SP03) on polyurethane biomaterial surfaces using a polyethylene glycol (PEG) linker. Compared to our previous approach to tether small molecules on surfaces using a short hexamethylene diisocyanate (HMDI) linker, the new modification resulted in surfaces enriched with a higher density of small molecules, SP02 and SP03. Studies of S. epidermidis and P. aeruginosa biofilm formation on surfaces demonstrated that PEG-linked surfaces were more resistant to biofilm formation than the HMDI-linked surfaces. The analysis of intracellular nucleotides in biofilm cells showed that the PEG-linked surfaces significantly reduced c-di-AMP levels in S. epidermidis cells and c-di-GMP levels in P. aeruginosa cells. In vivo experiments with a 7-day subcutaneous rat model suggest that the new small molecule tethered surfaces by the extended PEG linkers show increased resistance to microbial infection and are biocompatible to tissues. Overall, the results suggest that the PEG long linker can be used to tether small molecules on polyurethane biomaterial surfaces and retain the activity of small molecules, providing a new approach to combat microbial infections.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part A
Published
2026-03-26
DOI
https://doi.org/10.1002/jbm.a.70069
Primary Topic
Antimicrobial agents and applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anti‐Biofilm Properties of Polyurethane Biomaterials Tethered With Small Molecules via Polyethylene Glycol Linker

J. Y. Liu, Harry R. Allcock, Jennifer L. Booth, Christopher A. Siedlecki et al.
Journal of Biomedical Materials Research Part A
Antimicrobial agents and applications
article

Anti‐Biofilm Properties of Polyurethane Biomaterials Tethered With Small Molecules via Polyethylene Glycol Linker

J. Y. Liu, Harry R. Allcock, Jennifer L. Booth, Christopher A. Siedlecki, Li‐Chong Xu, Matthew Lanza, Dongxiao Sun, Chen Chen
article en

Abstract

Biofilm-associated microbial infection is one of the main complications for long-term use of biomaterials in implantable medical devices. Bacterial intracellular nucleotide second messenger signaling is widely recognized to be involved in biofilm formation and assists bacteria in monitoring and responding appropriately to changing environments. Interference with the nucleotide signaling mechanisms by small molecules to interrupt biofilm formation provides a novel way to control microbial infection on biomaterial surfaces. This study reports an approach to tether small molecule derivatives of 4-arylazo-3,5-diamino-1 H-pyrazole (termed as SP02 and SP03) on polyurethane biomaterial surfaces using a polyethylene glycol (PEG) linker. Compared to our previous approach to tether small molecules on surfaces using a short hexamethylene diisocyanate (HMDI) linker, the new modification resulted in surfaces enriched with a higher density of small molecules, SP02 and SP03. Studies of S. epidermidis and P. aeruginosa biofilm formation on surfaces demonstrated that PEG-linked surfaces were more resistant to biofilm formation than the HMDI-linked surfaces. The analysis of intracellular nucleotides in biofilm cells showed that the PEG-linked surfaces significantly reduced c-di-AMP levels in S. epidermidis cells and c-di-GMP levels in P. aeruginosa cells. In vivo experiments with a 7-day subcutaneous rat model suggest that the new small molecule tethered surfaces by the extended PEG linkers show increased resistance to microbial infection and are biocompatible to tissues. Overall, the results suggest that the PEG long linker can be used to tether small molecules on polyurethane biomaterial surfaces and retain the activity of small molecules, providing a new approach to combat microbial infections.

Journal of Biomedical Materials Research Part AVol. 114(4)
Pennsylvania State University (US), Penn State Milton S. Hershey Medical Center (US)
Openalex Percentile: Top 5%
Antimicrobial agents and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.