Critical overload ignition of XLPE-insulated low-voltage wires: thresholds, fire kinetics and STA-FTIR-based mechanistic interpretation

With increasing end-use electrification, low-voltage distribution wires are subjected to higher overload currents and greater fire risk; however, the ignition thresholds and combustion responses of XLPE-insulated wires remain insufficiently quantified. A 2.5 mm 2 copper-core XLPE wire was tested under steady overload currents of 100–240 A to reproduce self-ignition without an external ignition source, and STA-FTIR was used to characterize the oxidative pyrolysis of the pristine insulation in air. Self-ignition occurred at a critical current of 140 A. Smoke-onset time decreased approximately linearly with current, whereas ignition time followed an exponential decay. The flaming duration showed a non-monotonic trend, peaking at 27 s at 180 A and then shortening at higher currents as earlier fusing reduced the effective fuel-supply window. Maximum flame height and axial spread distance increased with current, with the strongest unsteady fluctuations at 200–220 A and a spread plateau of 75–80 cm above 210 A. STA-FTIR indicates pyrolysis onset near 450 K and a main decomposition peak at 700–750 K, releasing mainly light (partly unsaturated) hydrocarbons together with CO 2 , H 2 O and minor C–O-bearing volatiles. Combining both datasets, a Joule-heating–pyrolysis–near-surface accumulation/auto-ignition framework is proposed to support overload fire-threshold identification and early-warning parameterization. • Critical ignition current of XLPE-insulated wires under overload is identified. • Overload current controls ignition delay and flame spread kinetics. • Joule heating–driven pyrolysis governs source-free ignition behavior.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-03-27
DOI
https://doi.org/10.1016/j.csite.2026.107982
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Critical overload ignition of XLPE-insulated low-voltage wires: thresholds, fire kinetics and STA-FTIR-based mechanistic interpretation

Ruichao WEI, Zhurong Dong, Songfeng Liang, Shenshi Huang et al.
Case Studies in Thermal Engineering
Fire dynamics and safety research
article

Critical overload ignition of XLPE-insulated low-voltage wires: thresholds, fire kinetics and STA-FTIR-based mechanistic interpretation

Ruichao WEI, Zhurong Dong, Songfeng Liang, Shenshi Huang, Qingwen Lin, Zhanyu Li, Jun Deng, Shu Zhang, Yang Li
article en

Abstract

With increasing end-use electrification, low-voltage distribution wires are subjected to higher overload currents and greater fire risk; however, the ignition thresholds and combustion responses of XLPE-insulated wires remain insufficiently quantified. A 2.5 mm 2 copper-core XLPE wire was tested under steady overload currents of 100–240 A to reproduce self-ignition without an external ignition source, and STA-FTIR was used to characterize the oxidative pyrolysis of the pristine insulation in air. Self-ignition occurred at a critical current of 140 A. Smoke-onset time decreased approximately linearly with current, whereas ignition time followed an exponential decay. The flaming duration showed a non-monotonic trend, peaking at 27 s at 180 A and then shortening at higher currents as earlier fusing reduced the effective fuel-supply window. Maximum flame height and axial spread distance increased with current, with the strongest unsteady fluctuations at 200–220 A and a spread plateau of 75–80 cm above 210 A. STA-FTIR indicates pyrolysis onset near 450 K and a main decomposition peak at 700–750 K, releasing mainly light (partly unsaturated) hydrocarbons together with CO 2 , H 2 O and minor C–O-bearing volatiles. Combining both datasets, a Joule-heating–pyrolysis–near-surface accumulation/auto-ignition framework is proposed to support overload fire-threshold identification and early-warning parameterization. • Critical ignition current of XLPE-insulated wires under overload is identified. • Overload current controls ignition delay and flame spread kinetics. • Joule heating–driven pyrolysis governs source-free ignition behavior.

Case Studies in Thermal EngineeringVol. 81
Xi'an University of Science and Technology (CN), Shenzhen Polytechnic University (CN), China People's Police University (CN)
Affordable and clean energy
Openalex Percentile: Top 4%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.