Pediatric Diagnostic Reference Levels for Chest X‐Rays in the Northern Cape Province of South Africa: A Descriptive Study

ABSTRACT Background and Aims The International Commission on Radiological Protection emphasizes dose optimization for pediatric patients due to their higher radiosensitivity. Establishing diagnostic reference levels (DRLs) supports this goal during radiological examinations. This study aimed to establish pediatric diagnostic reference levels (PiDRLs) for anteroposterior (AP) chest X‐rays across four hospitals in the Northern Cape Province, South Africa. Methods PiDRLs were calculated for 375 pediatric patients (birth to 12 years) categorized by weight bands and age groups. Image quality was assessed using an image quality assessment checklist. DRLs were determined as the 75th percentile of the dose distribution for fixed X‐ray units. An image quality assessment was performed to establish if the dose levels consistently produced images of acceptable diagnostic quality. Results Mean PiDRLs for weight groups < 5 kg, 5– < 15 kg, 15– < 30 kg, 30– < 50 kg were 0.2 mGy, 0.2 mGy, 0.2 mGy, and 0.3 mGy, respectively. Corresponding values for age groups < 1 year, 1– < 5 years, 5– < 10 years, and 10– < 12 years were 0.2 mGy, 0.2 mGy, 0.3 mGy, and 0.3 mGy, respectively. Image quality was consistently high, with the 75th percentile slightly exceeding international benchmarks. The image quality assessment confirmed that the dose levels produced images of acceptable image quality. Conclusion PiDRLs match select international benchmarks, offering a baseline for South African optimization. This study contributes valuable regional data to support radiation safety and dose optimization in pediatric medical imaging in South Africa.

Authors

Institutions

Publication Details

Journal
Health Science Reports
Published
2026-03-26
DOI
https://doi.org/10.1002/hsr2.72185
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pediatric Diagnostic Reference Levels for Chest X‐Rays in the Northern Cape Province of South Africa: A Descriptive Study

H. Muller, O. L. Lackay, J. Horn‐Lodewyk
Health Science Reports
Radiation Dose and Imaging
article

Pediatric Diagnostic Reference Levels for Chest X‐Rays in the Northern Cape Province of South Africa: A Descriptive Study

H. Muller, O. L. Lackay, J. Horn‐Lodewyk
article en

Abstract

ABSTRACT Background and Aims The International Commission on Radiological Protection emphasizes dose optimization for pediatric patients due to their higher radiosensitivity. Establishing diagnostic reference levels (DRLs) supports this goal during radiological examinations. This study aimed to establish pediatric diagnostic reference levels (PiDRLs) for anteroposterior (AP) chest X‐rays across four hospitals in the Northern Cape Province, South Africa. Methods PiDRLs were calculated for 375 pediatric patients (birth to 12 years) categorized by weight bands and age groups. Image quality was assessed using an image quality assessment checklist. DRLs were determined as the 75th percentile of the dose distribution for fixed X‐ray units. An image quality assessment was performed to establish if the dose levels consistently produced images of acceptable diagnostic quality. Results Mean PiDRLs for weight groups < 5 kg, 5– < 15 kg, 15– < 30 kg, 30– < 50 kg were 0.2 mGy, 0.2 mGy, 0.2 mGy, and 0.3 mGy, respectively. Corresponding values for age groups < 1 year, 1– < 5 years, 5– < 10 years, and 10– < 12 years were 0.2 mGy, 0.2 mGy, 0.3 mGy, and 0.3 mGy, respectively. Image quality was consistently high, with the 75th percentile slightly exceeding international benchmarks. The image quality assessment confirmed that the dose levels produced images of acceptable image quality. Conclusion PiDRLs match select international benchmarks, offering a baseline for South African optimization. This study contributes valuable regional data to support radiation safety and dose optimization in pediatric medical imaging in South Africa.

Health Science ReportsVol. 9(4)
Central University of Technology (ZA), Pacific Radiology (New Zealand) (NZ)
Partnerships for the goals
Openalex Percentile: Top 6%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.