Correction of Respiratory Motion in Free‐Breathing DCE‐MRI Using a Pilot‐Tone Coil

Respiratory motion poses a major challenge in abdominopelvic MRI and often leads to strong artifacts. Self-navigation techniques have been proposed for motion correction, allowing free-breathing examination. However, self-navigation methods typically fail to track respiratory motion for dynamic contrast-enhanced (DCE) scans due to concurrent signal changes caused by the contrast injection. In this study, we investigated the use of a pilot-tone (PT) transmitter integrated into the receive coil as an alternative approach for obtaining respiratory curves. The amplitude of the received PT signal gets modulated by respiratory motion due to changes in the coil load. A pipeline for extracting respiratory curves from the PT signal was developed and applied for motion-corrected free-breathing abdominal DCE-MRI. Validation experiments included real-time cine imaging and comparison with self-navigation for five late-phase liver scans. Dynamic experiments were performed for a liver DCE scan of one healthy volunteer and kidney DCE scans of 24 patients. A motion-weighted GRASP algorithm was used for reconstructing dynamic images. Quantitative metrics, including gradient entropy for individual images and the L2 norm of the temporal differences for each dynamic frame set, were calculated. Motion-weighted DCE GRASP reconstructions using PT-derived respiratory curves showed improved image sharpness, especially in regions such as the diaphragm, kidney boundaries, and vessels, as well as better temporal consistency compared to conventional GRASP reconstructions. These improvements were observed both qualitatively and quantitatively. This work demonstrates that the PT technique can accurately detect respiration during contrast injections, reducing motion blurring in free-breathing dynamic DCE-MRI. The proposed technique can be easily implemented in the clinical workflow by using a coil with an integrated PT transmitter and requires no external belts or sensors.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-03-27
DOI
https://doi.org/10.1002/nbm.70278
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correction of Respiratory Motion in Free‐Breathing DCE‐MRI Using a Pilot‐Tone Coil

Kai Tobias Block, Ruoxun Zi, Peter Speier, Mario Bacher et al.
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

Correction of Respiratory Motion in Free‐Breathing DCE‐MRI Using a Pilot‐Tone Coil

Kai Tobias Block, Ruoxun Zi, Peter Speier, Mario Bacher, Hersh Chandarana, Riccardo Lattanzi
article en

Abstract

Respiratory motion poses a major challenge in abdominopelvic MRI and often leads to strong artifacts. Self-navigation techniques have been proposed for motion correction, allowing free-breathing examination. However, self-navigation methods typically fail to track respiratory motion for dynamic contrast-enhanced (DCE) scans due to concurrent signal changes caused by the contrast injection. In this study, we investigated the use of a pilot-tone (PT) transmitter integrated into the receive coil as an alternative approach for obtaining respiratory curves. The amplitude of the received PT signal gets modulated by respiratory motion due to changes in the coil load. A pipeline for extracting respiratory curves from the PT signal was developed and applied for motion-corrected free-breathing abdominal DCE-MRI. Validation experiments included real-time cine imaging and comparison with self-navigation for five late-phase liver scans. Dynamic experiments were performed for a liver DCE scan of one healthy volunteer and kidney DCE scans of 24 patients. A motion-weighted GRASP algorithm was used for reconstructing dynamic images. Quantitative metrics, including gradient entropy for individual images and the L2 norm of the temporal differences for each dynamic frame set, were calculated. Motion-weighted DCE GRASP reconstructions using PT-derived respiratory curves showed improved image sharpness, especially in regions such as the diaphragm, kidney boundaries, and vessels, as well as better temporal consistency compared to conventional GRASP reconstructions. These improvements were observed both qualitatively and quantitatively. This work demonstrates that the PT technique can accurately detect respiration during contrast injections, reducing motion blurring in free-breathing dynamic DCE-MRI. The proposed technique can be easily implemented in the clinical workflow by using a coil with an integrated PT transmitter and requires no external belts or sensors.

NMR in BiomedicineVol. 39(5)
Siemens Healthineers (Germany) (DE), New York University (US)
Openalex Percentile: Top 6%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.