Design and Characterization of the POKERINO Prototype for the POKER/NA64 Experiment at CERN

The NA64 experiment at the CERN H4 beamline recently started a high-energy positron-beam program to search for light dark matter particles through a thick-target, missing-energy measurement. To fulfill the energy resolution requirement of the physics measurement σE/E≃2.5%/E[GeV]⊕0.5% and cope with the constraints and performance requests of the NA64 setup, a new high-resolution homogeneous electromagnetic calorimeter PKR-CAL has been designed. The detector is based on PbWO4 crystals, each read by multiple SiPM sensors to maximize the light collection. The PKR-CAL design has been optimized to mitigate and control unavoidable SiPM saturation effects at high light levels, as well as to minimize the gain fluctuations induced by instantaneous variations of the H4 beam intensity. The R&D program culminated in the construction of a small-scale prototype, POKERINO. In this work, we present the results from the experimental characterization campaign of the POKERINO, aiming at demonstrating that the obtained performances are compatible with the application requirements.

Authors

Institutions

Publication Details

Journal
Instruments
Published
2026-03-27
DOI
https://doi.org/10.3390/instruments10020019
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Characterization of the POKERINO Prototype for the POKER/NA64 Experiment at CERN

A. Marini, A. Antonov, A. Celentano, L. Marsicano et al.
Instruments
Radiation Detection and Scintillator Technologies
article

Design and Characterization of the POKERINO Prototype for the POKER/NA64 Experiment at CERN

A. Marini, A. Antonov, A. Celentano, L. Marsicano, P. Bisio, M. Bondí
article en

Abstract

The NA64 experiment at the CERN H4 beamline recently started a high-energy positron-beam program to search for light dark matter particles through a thick-target, missing-energy measurement. To fulfill the energy resolution requirement of the physics measurement σE/E≃2.5%/E[GeV]⊕0.5% and cope with the constraints and performance requests of the NA64 setup, a new high-resolution homogeneous electromagnetic calorimeter PKR-CAL has been designed. The detector is based on PbWO4 crystals, each read by multiple SiPM sensors to maximize the light collection. The PKR-CAL design has been optimized to mitigate and control unavoidable SiPM saturation effects at high light levels, as well as to minimize the gain fluctuations induced by instantaneous variations of the H4 beam intensity. The R&D program culminated in the construction of a small-scale prototype, POKERINO. In this work, we present the results from the experimental characterization campaign of the POKERINO, aiming at demonstrating that the obtained performances are compatible with the application requirements.

InstrumentsVol. 10(2)
Istituto Nazionale di Fisica Nucleare, Sezione di Catania (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Genova (IT), University of Genoa (IT)
Affordable and clean energy
Openalex Percentile: Top 5%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.