Feasibility and accuracy of continuous glucose monitoring in surgical intensive care unit patients : a single-center pilot study in South Korea

CGM was feasible and acceptably accurate in ICU patients. Persistent hyperglycemia despite protocolized care indicates that CGM-derived data may help to identify opportunities for future protocol improvement. Its potential impact on the time-in-target range, hypoglycemia, and clinical outcomes should be evaluated in future multicenter studies.

Authors

Institutions

Publication Details

Journal
Acute and Critical Care
Published
2026-03-27
DOI
https://doi.org/10.4266/acc.004975
Primary Topic
Hyperglycemia and glycemic control in critically ill and hospitalized patients
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and accuracy of continuous glucose monitoring in surgical intensive care unit patients : a single-center pilot study in South Korea

Chi-min Park, Joon Ho Lee, Eunmi Gil, Hyojun Park
Acute and Critical Care
Hyperglycemia and glycemic control in critically ill and hospitalized patients
article

Feasibility and accuracy of continuous glucose monitoring in surgical intensive care unit patients : a single-center pilot study in South Korea

Chi-min Park, Joon Ho Lee, Eunmi Gil, Hyojun Park
article en

Abstract

CGM was feasible and acceptably accurate in ICU patients. Persistent hyperglycemia despite protocolized care indicates that CGM-derived data may help to identify opportunities for future protocol improvement. Its potential impact on the time-in-target range, hypoglycemia, and clinical outcomes should be evaluated in future multicenter studies.

Acute and Critical Care
Samsung Medical Center (KR)
Openalex Percentile: Top 6%
Hyperglycemia and glycemic control in critically ill and hospitalized patients
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Feasibility and accuracy of continuous glucose monitoring in surgical intensive care unit patients : a single-center pilot study in South Korea — Chi-min Park, Joon Ho Lee, et al. · Acute and Critical Care (2026) | TGRS Research Map | TGRS