Capacity Regression and Temperature Prediction for Canada’s Largest Solar Facility, Travers Solar, Alberta

Utility-scale photovoltaic (PV) plants rely on supervisory control and data acquisition (SCADA) streams for performance verification, yet high-frequency measurements are routinely affected by sensor dropouts, intermittency, and operating-state transitions that bias regression-based capacity estimates. This study evaluates a reproducible SCADA processing workflow for capacity-style reporting and a complementary soiling–clean temperature prediction model using data from a documented October 2022 test window (5 s SCADA aggregated to 1 min). The following three filtering approaches are compared: (i) naïve thresholds (Baseline A), (ii) deterministic stability screening using ramp-rate and rolling-variability constraints (Baseline B), and (iii) an optional residual-based outlier trimming step (Method C). Capacity is estimated via a multivariate regression evaluated on a fixed-size reporting-condition subset (RC197) with day-coverage constraints. All methods achieved high fit quality on RC197 (R2≈0.99), with Baseline B improving error and uncertainty over Baseline A (RMSE 2.05 vs. 2.18 MW; U95 0.97% vs. 1.03%) while preserving day coverage; Method C yielded the lowest in-sample RMSE (1.89 MW) but reduced day coverage. For temperature prediction, a baseline-plus-residual learning formulation substantially improved leave-one-day-out performance, reducing MAE/RMSE from 2.99/3.76 °C to 1.43/1.80 °C and increasing R2 from 0.60 to 0.91. The results highlight trade-offs between fit tightness and representativeness in capacity-style filtering and demonstrate residual learning is an effective approach for SCADA-based thermal characterization.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-03-27
DOI
https://doi.org/10.3390/pr14071078
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Capacity Regression and Temperature Prediction for Canada’s Largest Solar Facility, Travers Solar, Alberta

Shunde Yin, Yutong Chai, Walter Schachtschneider, Anthony Thai et al.
Processes
Photovoltaic System Optimization Techniques
article

Capacity Regression and Temperature Prediction for Canada’s Largest Solar Facility, Travers Solar, Alberta

Shunde Yin, Yutong Chai, Walter Schachtschneider, Anthony Thai, Geoffrey Bell, Tayo Oketola, Zhensen Gao
article en

Abstract

Utility-scale photovoltaic (PV) plants rely on supervisory control and data acquisition (SCADA) streams for performance verification, yet high-frequency measurements are routinely affected by sensor dropouts, intermittency, and operating-state transitions that bias regression-based capacity estimates. This study evaluates a reproducible SCADA processing workflow for capacity-style reporting and a complementary soiling–clean temperature prediction model using data from a documented October 2022 test window (5 s SCADA aggregated to 1 min). The following three filtering approaches are compared: (i) naïve thresholds (Baseline A), (ii) deterministic stability screening using ramp-rate and rolling-variability constraints (Baseline B), and (iii) an optional residual-based outlier trimming step (Method C). Capacity is estimated via a multivariate regression evaluated on a fixed-size reporting-condition subset (RC197) with day-coverage constraints. All methods achieved high fit quality on RC197 (R2≈0.99), with Baseline B improving error and uncertainty over Baseline A (RMSE 2.05 vs. 2.18 MW; U95 0.97% vs. 1.03%) while preserving day coverage; Method C yielded the lowest in-sample RMSE (1.89 MW) but reduced day coverage. For temperature prediction, a baseline-plus-residual learning formulation substantially improved leave-one-day-out performance, reducing MAE/RMSE from 2.99/3.76 °C to 1.43/1.80 °C and increasing R2 from 0.60 to 0.91. The results highlight trade-offs between fit tightness and representativeness in capacity-style filtering and demonstrate residual learning is an effective approach for SCADA-based thermal characterization.

ProcessesVol. 14(7)
University of Waterloo (CA)
Industry, innovation and infrastructure
Openalex Percentile: Top 9%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.