Design and Pilot Evaluation of an IoT-Based Blood Pressure Monitoring System for Rabbits

Telemedicine, driven by the Internet of Things (IoT) and wireless connectivity, is essential for managing cardiovascular diseases, where hypertension remains the primary risk factor. In preclinical research, rabbits are superior biological models compared to rodents due to their human-like lipid metabolism. However, continuous blood pressure monitoring in this species remains challenging. The gold-standard technique (direct carotid catheterization) requires terminal procedures, and indirect methods (Doppler, oscillometric) show limited agreement with direct measurements. Furthermore, commercially available implantable telemetry platforms, while enabling real-time monitoring in freely moving animals, require costly surgical implantation, specialized proprietary hardware, and post-operative recovery periods that may confound early hemodynamic data. To address these limitations, this study presents a low-cost, customizable, and minimally invasive monitoring system utilizing a pressure transducer in the central auricular artery. The device integrates an ESP32 microcontroller with IoT technology for digital signal processing and seamless wireless data transmission to the ThingSpeak cloud platform. Unlike implantable telemetry, the proposed approach avoids surgical implantation and its associated costs and recovery time, while still enabling continuous, real-time hemodynamic tracking throughout the experimental period. A pilot evaluation against the BIOPAC MP100 reference (carotid artery) demonstrated relative errors of 1.60% for mean arterial pressure, 8.58% for systolic blood pressure, and 2.43% for diastolic blood pressure. By reducing invasiveness and enhancing remote data accessibility, this system provides a promising framework for the preclinical evaluation of antihypertensive agents and cardiovascular mechanisms, bridging the gap between edge computing and remote clinical diagnostics.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-03-26
DOI
https://doi.org/10.3390/bioengineering13040384
Primary Topic
Cardiovascular Conditions and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Pilot Evaluation of an IoT-Based Blood Pressure Monitoring System for Rabbits

Carlos Exequiel Garay, Rossana E. Madrid, Susana Jeréz, Gonzalo Nicolás Mansilla et al.
Bioengineering
Cardiovascular Conditions and Treatments
article

Design and Pilot Evaluation of an IoT-Based Blood Pressure Monitoring System for Rabbits

Carlos Exequiel Garay, Rossana E. Madrid, Susana Jeréz, Gonzalo Nicolás Mansilla, Agustina González Colombres
article en

Abstract

Telemedicine, driven by the Internet of Things (IoT) and wireless connectivity, is essential for managing cardiovascular diseases, where hypertension remains the primary risk factor. In preclinical research, rabbits are superior biological models compared to rodents due to their human-like lipid metabolism. However, continuous blood pressure monitoring in this species remains challenging. The gold-standard technique (direct carotid catheterization) requires terminal procedures, and indirect methods (Doppler, oscillometric) show limited agreement with direct measurements. Furthermore, commercially available implantable telemetry platforms, while enabling real-time monitoring in freely moving animals, require costly surgical implantation, specialized proprietary hardware, and post-operative recovery periods that may confound early hemodynamic data. To address these limitations, this study presents a low-cost, customizable, and minimally invasive monitoring system utilizing a pressure transducer in the central auricular artery. The device integrates an ESP32 microcontroller with IoT technology for digital signal processing and seamless wireless data transmission to the ThingSpeak cloud platform. Unlike implantable telemetry, the proposed approach avoids surgical implantation and its associated costs and recovery time, while still enabling continuous, real-time hemodynamic tracking throughout the experimental period. A pilot evaluation against the BIOPAC MP100 reference (carotid artery) demonstrated relative errors of 1.60% for mean arterial pressure, 8.58% for systolic blood pressure, and 2.43% for diastolic blood pressure. By reducing invasiveness and enhancing remote data accessibility, this system provides a promising framework for the preclinical evaluation of antihypertensive agents and cardiovascular mechanisms, bridging the gap between edge computing and remote clinical diagnostics.

BioengineeringVol. 13(4)
National University of Tucumán (AR), National Technological University (AR), Instituto Superior de Investigaciones Biológicas (AR), Centro Científico Tecnológico - Tucumán (AR)
Openalex Percentile: Top 7%
Cardiovascular Conditions and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.