Characterization and Performance Assessment of HVOF Sprayed Tribaloy Coating Subjected to Cyclic Oxidation and Hot Corrosion Conditions

In high-temperature gas turbine applications, Co-based CoMoCrSi (Tribaloy T-400) coating was sprayed onto MDN420 steel with the help of a thermal spraying process (high-velocity oxy-fuel (HVOF)). Cyclic Oxidation and Hot Corrosion were tested at 700°C in a hot molten salt environment of 80 wt.% Na 2 SO 4 20 wt.% V 2 O 5 with each cycle taking 1 h exposure time and 20 min cooling to ambient temperature. The microstructure of the as-sprayed coating was dense and uniform with a surface roughness of 5.20 ± 0.35 µm, porosity of 2.25 ± 0.28%, and microhardness of 507.26 ± 20 H V , compared to the uncoated MDN420 substrate of 153.91± 12 H V . Scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) confirmed uniform splat morphology and homogeneous distribution of Co, Mo, Cr, and Si throughout the coating. Phase analysis using X-ray diffraction (XRD) identified a γ-Co solid-solution matrix being strengthened by Laves-type intermetallic phases, Co 3 Mo 2 Si, with trace Co 7 Mo 6 , Cr 3 Si and some amorphous phases. Cyclic Oxidation and hot corrosion kinetics provided parabolic rate constants (Kp) of 1.2 ×10 -9 and 7.6 ×10 -8 g 2 cm -4 s -1 respectively, lower than the rate constants of bare MDN420 steel. In the process of oxidation, uninterrupted Cr 2 O 3 and SiO 2 scales grew and inhibited the oxygen movement. When molten salts were exposed to coating constituents, there was a reaction between molten salt and coating constituents to give mixed oxides and vanadates like CoMoO 4 , Co 3 V 2 O 8 and NaVO 3 . The effect of stable oxide scales and thermally stable intermetallic phases was combined to significantly reduce the penetration of molten salts and degradation at high temperatures.

Authors

Institutions

Publication Details

Journal
Journal of Alloys and Metallurgical Systems
Published
2026-03-01
DOI
https://doi.org/10.1016/j.jalmes.2026.100244
Primary Topic
High-Temperature Coating Behaviors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization and Performance Assessment of HVOF Sprayed Tribaloy Coating Subjected to Cyclic Oxidation and Hot Corrosion Conditions

Subramanya R B Prabhu, C.Durga Prasad, K A Jayasheel Kumar, B N Deepak Kumar et al.
Journal of Alloys and Metallurgical Systems
High-Temperature Coating Behaviors
article

Characterization and Performance Assessment of HVOF Sprayed Tribaloy Coating Subjected to Cyclic Oxidation and Hot Corrosion Conditions

Subramanya R B Prabhu, C.Durga Prasad, K A Jayasheel Kumar, B N Deepak Kumar, S Suresh Kumar, S Sreenivas, M Praveen Kumar, B Sachin, Piyush Kumar Soni, G Padmavathi
article en

Abstract

In high-temperature gas turbine applications, Co-based CoMoCrSi (Tribaloy T-400) coating was sprayed onto MDN420 steel with the help of a thermal spraying process (high-velocity oxy-fuel (HVOF)). Cyclic Oxidation and Hot Corrosion were tested at 700°C in a hot molten salt environment of 80 wt.% Na 2 SO 4 20 wt.% V 2 O 5 with each cycle taking 1 h exposure time and 20 min cooling to ambient temperature. The microstructure of the as-sprayed coating was dense and uniform with a surface roughness of 5.20 ± 0.35 µm, porosity of 2.25 ± 0.28%, and microhardness of 507.26 ± 20 H V , compared to the uncoated MDN420 substrate of 153.91± 12 H V . Scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) confirmed uniform splat morphology and homogeneous distribution of Co, Mo, Cr, and Si throughout the coating. Phase analysis using X-ray diffraction (XRD) identified a γ-Co solid-solution matrix being strengthened by Laves-type intermetallic phases, Co 3 Mo 2 Si, with trace Co 7 Mo 6 , Cr 3 Si and some amorphous phases. Cyclic Oxidation and hot corrosion kinetics provided parabolic rate constants (Kp) of 1.2 ×10 -9 and 7.6 ×10 -8 g 2 cm -4 s -1 respectively, lower than the rate constants of bare MDN420 steel. In the process of oxidation, uninterrupted Cr 2 O 3 and SiO 2 scales grew and inhibited the oxygen movement. When molten salts were exposed to coating constituents, there was a reaction between molten salt and coating constituents to give mixed oxides and vanadates like CoMoO 4 , Co 3 V 2 O 8 and NaVO 3 . The effect of stable oxide scales and thermally stable intermetallic phases was combined to significantly reduce the penetration of molten salts and degradation at high temperatures.

Journal of Alloys and Metallurgical Systems
Manipal Academy of Higher Education (IN), Nightingales Medical Trust (IN), Dr. S.R. Chandrasekhar Institute of Speech and Hearing (IN), Mahindra University (IN), Ganpat University (IN), Massachusetts Institute of Technology (US), Visvesvaraya Technological University (IN), GITAM University (IN)
Affordable and clean energy
Openalex Percentile: Top 4%
High-Temperature Coating Behaviors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.