Local damage control in asymmetric single-pylon cable-stayed bridges with different pylon-girder restraint systems under seismic action

Asymmetric single-pylon cable-stayed bridges typically employ a pylon-girder rigid connection to balance the significant asymmetry in mass and stiffness. However, under strong seismic action, this conventional design leads to severe bending moment concentration in the joint zone, posing a high risk of local damage. To address this critical issue, this study proposes a vertical hinged connection system. This study focuses on an asymmetric single-pylon cable-stayed bridge with a total length of 320 m and a main span of 190 m. Utilizing dynamic time-history analysis, the global seismic responses and the detailed strain behavior in the joint zone under seismic excitation were systematically compared between the two systems, validating the effectiveness of the proposed vertical hinged connection in local damage control. The findings of the study indicate that in scenarios involving combined vertical and longitudinal seismic actions, the conventional rigid connection method gives rise to a significant concentration of bending moment in the joint zone. This is attributable to the effects of pylon offset and girder vertical bending, which collectively result in elevated strain levels and considerable local damage risk. Conversely, the vertical hinged connection effectively releases the girder's rotational degree of freedom about the transverse direction, thereby eliminating bending moment in the joint zone induced by pylon offset and girder vertical bending during earthquakes. This approach has been shown to significantly reduce principal strains in both the girder and the lower pylon segment within the joint area, thereby mitigating the risk of cracking at the girder-pylon joint. The findings provide a valuable reference for the seismic design of pylon-girder restraint systems in asymmetric single-pylon cable-stayed bridges aimed at local damage control.

Authors

Institutions

Publication Details

Journal
Earthquake research advances
Published
2026-03-01
DOI
https://doi.org/10.1016/j.eqrea.2026.100460
Primary Topic
Structural Engineering and Vibration Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Local damage control in asymmetric single-pylon cable-stayed bridges with different pylon-girder restraint systems under seismic action

Xiangliang Tang, Hongwei Liu, Xuan Tang, Yonghao Zhou et al.
Earthquake research advances
Structural Engineering and Vibration Analysis
article

Local damage control in asymmetric single-pylon cable-stayed bridges with different pylon-girder restraint systems under seismic action

Xiangliang Tang, Hongwei Liu, Xuan Tang, Yonghao Zhou, Jiaxin Chu
article en

Abstract

Asymmetric single-pylon cable-stayed bridges typically employ a pylon-girder rigid connection to balance the significant asymmetry in mass and stiffness. However, under strong seismic action, this conventional design leads to severe bending moment concentration in the joint zone, posing a high risk of local damage. To address this critical issue, this study proposes a vertical hinged connection system. This study focuses on an asymmetric single-pylon cable-stayed bridge with a total length of 320 m and a main span of 190 m. Utilizing dynamic time-history analysis, the global seismic responses and the detailed strain behavior in the joint zone under seismic excitation were systematically compared between the two systems, validating the effectiveness of the proposed vertical hinged connection in local damage control. The findings of the study indicate that in scenarios involving combined vertical and longitudinal seismic actions, the conventional rigid connection method gives rise to a significant concentration of bending moment in the joint zone. This is attributable to the effects of pylon offset and girder vertical bending, which collectively result in elevated strain levels and considerable local damage risk. Conversely, the vertical hinged connection effectively releases the girder's rotational degree of freedom about the transverse direction, thereby eliminating bending moment in the joint zone induced by pylon offset and girder vertical bending during earthquakes. This approach has been shown to significantly reduce principal strains in both the girder and the lower pylon segment within the joint area, thereby mitigating the risk of cracking at the girder-pylon joint. The findings provide a valuable reference for the seismic design of pylon-girder restraint systems in asymmetric single-pylon cable-stayed bridges aimed at local damage control.

Earthquake research advances
Fuyang Normal University (CN), Fuyang Maternity and Child Health Care Hospital (CN), Southwest Jiaotong University (CN)
Openalex Percentile: Top 6%
Structural Engineering and Vibration Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.