Monotonic and Fatigue Strength of 3D-Printed Partially Stabilized Zirconia for Monolithic Restorations

To investigate the monotonic and fatigue strength of 3D-printed 5 mol% yttria partially stabilized zirconia (5Y-PSZ) and the influences of printing layer orientation and finishing protocol. Bar-shaped 5Y-PSZ specimens (1.0 mm x 1.0 mm x 12.0 mm) were 3D-printed via stereolithography, followed by debinding and sintering. The specimens were randomly divided into 2 groups according to printing layer orientations: parallel or perpendicular to the tensile surface of a 3-point bending test. The specimens of each printing layer orientation were subsequently submitted to different surface finishing protocols: as-sintered, polished, and glazed. The monotonic strength of each group was determined using a ball-in-hole device. A step-wise fatigue test was conducted for the polished and glazed specimens. For monotonic strength, the parallel specimens (640 ± 99 MPa) were stronger than the perpendicular (507 ± 48 MPa); polishing generated higher strength for both parallel (782 ± 134 MPa) and perpendicular (645 ± 160 MPa) orientations; while the effect of glazing was not significant, the glazed perpendicular specimen (623 ± 97 MPa) presented similar strength to the glazed parallel specimens (581 ± 117 MPa). However, the fatigue strength was similar in the evaluated groups (parallel and polished: 418 ± 115 MPa; perpendicular and polished: 404 ± 55 MPa; parallel and glazed: 406 ± 41 MPa; perpendicular and glazed: 371 ± 86 MPa). Both printing layer orientation and surface finishing influenced the monotonic strength of 3D-printed 5Y-PSZ, while fatigue strength did not differ significantly among polished and glazed specimens with different orientations.

Authors

Institutions

Publication Details

Journal
International Dental Journal
Published
2026-03-28
DOI
https://doi.org/10.1016/j.identj.2026.109529
Primary Topic
Additive Manufacturing and 3D Printing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monotonic and Fatigue Strength of 3D-Printed Partially Stabilized Zirconia for Monolithic Restorations

Cornelis J. Kleverlaan, Amanda Maria de Oliveira Dal Piva, János Kodolányi, João Paulo Mendes Tribst et al.
International Dental Journal
Additive Manufacturing and 3D Printing Technologies
article

Monotonic and Fatigue Strength of 3D-Printed Partially Stabilized Zirconia for Monolithic Restorations

Cornelis J. Kleverlaan, Amanda Maria de Oliveira Dal Piva, János Kodolányi, João Paulo Mendes Tribst, Albert J. Feilzer, Li Wang, Yuqing Lu
article en

Abstract

To investigate the monotonic and fatigue strength of 3D-printed 5 mol% yttria partially stabilized zirconia (5Y-PSZ) and the influences of printing layer orientation and finishing protocol. Bar-shaped 5Y-PSZ specimens (1.0 mm x 1.0 mm x 12.0 mm) were 3D-printed via stereolithography, followed by debinding and sintering. The specimens were randomly divided into 2 groups according to printing layer orientations: parallel or perpendicular to the tensile surface of a 3-point bending test. The specimens of each printing layer orientation were subsequently submitted to different surface finishing protocols: as-sintered, polished, and glazed. The monotonic strength of each group was determined using a ball-in-hole device. A step-wise fatigue test was conducted for the polished and glazed specimens. For monotonic strength, the parallel specimens (640 ± 99 MPa) were stronger than the perpendicular (507 ± 48 MPa); polishing generated higher strength for both parallel (782 ± 134 MPa) and perpendicular (645 ± 160 MPa) orientations; while the effect of glazing was not significant, the glazed perpendicular specimen (623 ± 97 MPa) presented similar strength to the glazed parallel specimens (581 ± 117 MPa). However, the fatigue strength was similar in the evaluated groups (parallel and polished: 418 ± 115 MPa; perpendicular and polished: 404 ± 55 MPa; parallel and glazed: 406 ± 41 MPa; perpendicular and glazed: 371 ± 86 MPa). Both printing layer orientation and surface finishing influenced the monotonic strength of 3D-printed 5Y-PSZ, while fatigue strength did not differ significantly among polished and glazed specimens with different orientations.

International Dental JournalVol. 76(3)
Jiangnan University (CN), Academic Center for Dentistry Amsterdam (NL), Vrije Universiteit Amsterdam (NL), University of Amsterdam (NL)
Sustainable cities and communities
Openalex Percentile: Top 6%
Additive Manufacturing and 3D Printing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.