Clinical indication–based CT scan range reduction: A scoping review of radiation dose savings and diagnostic accuracy

Clinical indication-driven optimisation of CT scan range achieves substantial radiation-dose reduction without compromising diagnostic accuracy. These findings support evidence-based adoption of landmark-based protocols for focused clinical questions, with selective application in patients with broader differential diagnoses. Future directions include AI-assisted landmark detection and automated planning tools to enhance reproducibility and workflow efficiency.

Authors

Institutions

Publication Details

Journal
Journal of medical imaging and radiation sciences
Published
2026-03-27
DOI
https://doi.org/10.1016/j.jmir.2026.102338
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical indication–based CT scan range reduction: A scoping review of radiation dose savings and diagnostic accuracy

Yasser H. Hadi, Laura McLaughlin, Mo’men Bani-Ahmad, Aoife O Sullivan et al.
Journal of medical imaging and radiation sciences
Radiation Dose and Imaging
article

Clinical indication–based CT scan range reduction: A scoping review of radiation dose savings and diagnostic accuracy

Yasser H. Hadi, Laura McLaughlin, Mo’men Bani-Ahmad, Aoife O Sullivan, Andrew England, Mark McEntee
article en

Abstract

Clinical indication-driven optimisation of CT scan range achieves substantial radiation-dose reduction without compromising diagnostic accuracy. These findings support evidence-based adoption of landmark-based protocols for focused clinical questions, with selective application in patients with broader differential diagnoses. Future directions include AI-assisted landmark detection and automated planning tools to enhance reproducibility and workflow efficiency.

Journal of medical imaging and radiation sciencesVol. 57(3)
Hashemite University (JO), University of Southern Denmark (DK), University College Cork (IE), King Abdullah Medical City (SA)
Openalex Percentile: Top 7%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Clinical indication–based CT scan range reduction: A scoping review of radiation dose savings and diagnostic accuracy — Yasser H. Hadi, Laura McLaughlin, et al. · Journal of medical imaging and radiation sciences (2026) | TGRS Research Map | TGRS