Anisotropy in Dry‐Type Valve‐Side Bushings of Converter Transformer: Phenomena and Effects

ABSTRACT The safe and stable working of dry‐type valve‐side bushings, important components of converter transformers, is essential. In recent years, poor design has led to several core breakdown, flashover and cracking failures. The bushing cores, composed of crepe paper and aluminium foil, exhibit significant anisotropic physical properties due to its arrangement. However, in previous designs and simulations, the epoxy resin impregnated paper (ERIP) material of the core is often treated as isotropic, and even combined with aluminium foil for the thermal and mechanical calculations. This simplification results in considerable deviations between simulated and actual performance. In this paper, radial and axial ERIP slices are prepared and their electrical, thermal and mechanical anisotropy parameters are measured. A new modelling method of bushing anisotropy is proposed. Based on COMSOL Multiphysics 6.2, the electrical–thermal–mechanical–fluid simulation model of ± 800 kV dry‐type valve‐side bushing is established. The results indicate that the anisotropic model exhibits a 19.1% higher temperature rise, a 15.2% higher maximum radial field strength, and an 85.7% lower damage stress margin than those of the isotropic model. These results show that bushing anisotropy cannot be ignored in modelling and design.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2026-03-26
DOI
https://doi.org/10.1049/hve2.70166
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anisotropy in Dry‐Type Valve‐Side Bushings of Converter Transformer: Phenomena and Effects

Gaoyi Shang, Xueyang Bai, Hong Tang, J. Li et al.
High Voltage
Power Transformer Diagnostics and Insulation
article

Anisotropy in Dry‐Type Valve‐Side Bushings of Converter Transformer: Phenomena and Effects

Gaoyi Shang, Xueyang Bai, Hong Tang, J. Li, Shuqi Zhang, Xuandong Liu, Wanhao Shi
article en

Abstract

ABSTRACT The safe and stable working of dry‐type valve‐side bushings, important components of converter transformers, is essential. In recent years, poor design has led to several core breakdown, flashover and cracking failures. The bushing cores, composed of crepe paper and aluminium foil, exhibit significant anisotropic physical properties due to its arrangement. However, in previous designs and simulations, the epoxy resin impregnated paper (ERIP) material of the core is often treated as isotropic, and even combined with aluminium foil for the thermal and mechanical calculations. This simplification results in considerable deviations between simulated and actual performance. In this paper, radial and axial ERIP slices are prepared and their electrical, thermal and mechanical anisotropy parameters are measured. A new modelling method of bushing anisotropy is proposed. Based on COMSOL Multiphysics 6.2, the electrical–thermal–mechanical–fluid simulation model of ± 800 kV dry‐type valve‐side bushing is established. The results indicate that the anisotropic model exhibits a 19.1% higher temperature rise, a 15.2% higher maximum radial field strength, and an 85.7% lower damage stress margin than those of the isotropic model. These results show that bushing anisotropy cannot be ignored in modelling and design.

High Voltage
North China Electric Power University (CN), State Grid Corporation of China (China) (CN), China Electric Power Research Institute, Xi'an Jiaotong University (CN)
Openalex Percentile: Top 6%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Anisotropy in Dry‐Type Valve‐Side Bushings of Converter Transformer: Phenomena and Effects — Gaoyi Shang, Xueyang Bai, et al. · High Voltage (2026) | TGRS Research Map | TGRS