SRS136 - A comparative study of wire-guided <i>versus</i> pintuation-guided wide local excision in breast cancer surgery

Abstract Background Accurate localisation is essential in breast-conserving surgery to ensure oncological safety while maintaining cosmesis. Wire-guided localisation (WGL) has long been the standard, though it presents limitations including patient discomfort and logistical challenges. This study compares surgical outcomes between WGL and a novel pintuation-guided excision technique in breast cancer patients undergoing wide local excision. Methods A retrospective cohort study was conducted involving 100 patients with early-stage breast cancer undergoing breast-conserving surgery between [June 2024-July 2025]. Fifty patients underwent wire-guided localisation, while fifty underwent pintuation-guided excision, a technique involving pre-operative localisation . Data collected included margin status, re-excision rates, operative time, and patient-reported outcomes. Results Pintuation-guided excision demonstrated superior outcomes in several key areas:Clear margin rates were significantly higher in the pintuation group (94%) compared to the wire-guided group (82%) (P &amp;lt; 0.05).Re-excision rates were lower in the pintuation group (6 versus 18%).Operative time was reduced by an average of 12 min in the pintuation group.Patient-reported satisfaction with the localisation process was higher in the pintuation group. No significant difference was observed in post-operative complications or pathology findings between the two groups. Conclusions Pintuation-guided excision appears to be a safe and effective alternative to wire-guided localisation in breast-conserving surgery, offering improved margin clearance, reduced re-excision rates, and better patient experience. Further prospective studies are warranted to validate these findings and assess long-term outcomes.

Authors

Institutions

Publication Details

Journal
British journal of surgery
Published
2026-03-01
DOI
https://doi.org/10.1093/bjs/znag018.132
Primary Topic
Breast Cancer Treatment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SRS136 - A comparative study of wire-guided versus pintuation-guided wide local excision in breast cancer surgery

Islam Mansy
British journal of surgery
Breast Cancer Treatment Studies
article

SRS136 - A comparative study of wire-guided versus pintuation-guided wide local excision in breast cancer surgery

Islam Mansy
article en

Abstract

Abstract Background Accurate localisation is essential in breast-conserving surgery to ensure oncological safety while maintaining cosmesis. Wire-guided localisation (WGL) has long been the standard, though it presents limitations including patient discomfort and logistical challenges. This study compares surgical outcomes between WGL and a novel pintuation-guided excision technique in breast cancer patients undergoing wide local excision. Methods A retrospective cohort study was conducted involving 100 patients with early-stage breast cancer undergoing breast-conserving surgery between [June 2024-July 2025]. Fifty patients underwent wire-guided localisation, while fifty underwent pintuation-guided excision, a technique involving pre-operative localisation . Data collected included margin status, re-excision rates, operative time, and patient-reported outcomes. Results Pintuation-guided excision demonstrated superior outcomes in several key areas:Clear margin rates were significantly higher in the pintuation group (94%) compared to the wire-guided group (82%) (P &amp;lt; 0.05).Re-excision rates were lower in the pintuation group (6 versus 18%).Operative time was reduced by an average of 12 min in the pintuation group.Patient-reported satisfaction with the localisation process was higher in the pintuation group. No significant difference was observed in post-operative complications or pathology findings between the two groups. Conclusions Pintuation-guided excision appears to be a safe and effective alternative to wire-guided localisation in breast-conserving surgery, offering improved margin clearance, reduced re-excision rates, and better patient experience. Further prospective studies are warranted to validate these findings and assess long-term outcomes.

British journal of surgeryVol. 113(Supplement_2)
Chelsea and Westminster Hospital NHS Foundation Trust (GB)
Good health and well-being
Openalex Percentile: Top 7%
Breast Cancer Treatment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

SRS136 - A comparative study of wire-guided <i>versus</i> pintuation-guided wide local excision in breast cancer surgery — Islam Mansy · British journal of surgery (2026) | TGRS Research Map | TGRS