Internal Flow, Vibration, and Noise Characteristics of a Magnetic Pump at Different Rotational Speeds

A high-speed magnetic pump rated at 7800 r/min was studied. A numerical model was established, and a hydraulic, vibration, and noise testing system was set up to conduct flow simulations, noise, and vibration experiments at different speeds. The results show that increasing speed leads to a higher pressure difference between the pump chamber and the cooling circuit. Meanwhile, the turbulent kinetic energy at the impeller outlet increases. Despite an increase in energy loss, the loss ratio decreases, and overall efficiency improves. The internal flow noise collected by the outlet hydrophone mainly comes from Rotor–Stator Interference (RSI), and it can sensitively capture changes in rotational speed. The dominant frequency of the outlet noise agrees well with the blade frequency calculated from the set speed, with a maximum deviation of 0.26%. As the speed increases, the overall sound pressure level (OASPL) at the inlet and outlet and the Root Mean Square (RMS) acceleration values at the outlet and pump body generally increase, while the acceleration at the motor base shows a decreasing trend. The conclusions are helpful for the design and optimization of rotary machinery such as high-speed magnetic pumps.

Authors

Institutions

Publication Details

Journal
Water
Published
2026-03-26
DOI
https://doi.org/10.3390/w18070784
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Internal Flow, Vibration, and Noise Characteristics of a Magnetic Pump at Different Rotational Speeds

Bin Xia, Fei Zhao, Fanyu Kong
Water
Cavitation Phenomena in Pumps
article

Internal Flow, Vibration, and Noise Characteristics of a Magnetic Pump at Different Rotational Speeds

Bin Xia, Fei Zhao, Fanyu Kong
article en

Abstract

A high-speed magnetic pump rated at 7800 r/min was studied. A numerical model was established, and a hydraulic, vibration, and noise testing system was set up to conduct flow simulations, noise, and vibration experiments at different speeds. The results show that increasing speed leads to a higher pressure difference between the pump chamber and the cooling circuit. Meanwhile, the turbulent kinetic energy at the impeller outlet increases. Despite an increase in energy loss, the loss ratio decreases, and overall efficiency improves. The internal flow noise collected by the outlet hydrophone mainly comes from Rotor–Stator Interference (RSI), and it can sensitively capture changes in rotational speed. The dominant frequency of the outlet noise agrees well with the blade frequency calculated from the set speed, with a maximum deviation of 0.26%. As the speed increases, the overall sound pressure level (OASPL) at the inlet and outlet and the Root Mean Square (RMS) acceleration values at the outlet and pump body generally increase, while the acceleration at the motor base shows a decreasing trend. The conclusions are helpful for the design and optimization of rotary machinery such as high-speed magnetic pumps.

WaterVol. 18(7)
Jiangsu University (CN), Wuxi Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 7%
Cavitation Phenomena in Pumps
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.