Display-Based Augmented Reality Navigation for CT-Guided Thoracoabdominal Punctures: Phantom Study of Accuracy and Workflow Efficiency

Accurate needle placement is critical in percutaneous thoracoabdominal interventions. Conventional CT-guided procedures are limited by iterative scans, operator-dependent variability, and two-dimensional visualization. This preclinical study evaluates a novel display-based augmented reality (AR) navigation system integrating virtual-to-real registration via deltille grid position sensing (DGPS) markers for enhanced needle guidance. Experiments were conducted on a CIRS abdominal phantom with three operators: one expert interventional radiologist and two novices. Puncture accuracy, angular deviation, procedure time, and number of verification scans were assessed. AR guidance achieved first-pass distance errors of 1.50 (0.46) mm for the expert and 1.66 (0.50) mm and 1.58 (1.06) mm for novices, with angular deviations of 1.41°, 1.30°, and 1.39°, respectively. No significant operator-related differences were observed. Compared with conventional step-and-shoot CT guidance, AR guidance reduced the first-pass and final-pass targeting error, while conventional CT guidance relies on iterative scan-adjust-advance steps to achieve acceptable final accuracy, with AR reducing intermediate re-scans while retaining a single final verification scan. The findings indicate that AR navigation enhances first-pass precision, reduces procedural variability, and improves workflow efficiency, supporting its potential clinical value for more consistent and efficient minimally invasive interventions.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-03-27
DOI
https://doi.org/10.1088/2057-1976/ae5827
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Display-Based Augmented Reality Navigation for CT-Guided Thoracoabdominal Punctures: Phantom Study of Accuracy and Workflow Efficiency

Penggang Bai, Zhuting Fang, Xiaolong Wang, Binwei He et al.
Biomedical Physics & Engineering Express
Augmented Reality Applications
article

Display-Based Augmented Reality Navigation for CT-Guided Thoracoabdominal Punctures: Phantom Study of Accuracy and Workflow Efficiency

Penggang Bai, Zhuting Fang, Xiaolong Wang, Binwei He, Tiansheng Liu, Xuhui Jiang, Jihong Chen
article en

Abstract

Accurate needle placement is critical in percutaneous thoracoabdominal interventions. Conventional CT-guided procedures are limited by iterative scans, operator-dependent variability, and two-dimensional visualization. This preclinical study evaluates a novel display-based augmented reality (AR) navigation system integrating virtual-to-real registration via deltille grid position sensing (DGPS) markers for enhanced needle guidance. Experiments were conducted on a CIRS abdominal phantom with three operators: one expert interventional radiologist and two novices. Puncture accuracy, angular deviation, procedure time, and number of verification scans were assessed. AR guidance achieved first-pass distance errors of 1.50 (0.46) mm for the expert and 1.66 (0.50) mm and 1.58 (1.06) mm for novices, with angular deviations of 1.41°, 1.30°, and 1.39°, respectively. No significant operator-related differences were observed. Compared with conventional step-and-shoot CT guidance, AR guidance reduced the first-pass and final-pass targeting error, while conventional CT guidance relies on iterative scan-adjust-advance steps to achieve acceptable final accuracy, with AR reducing intermediate re-scans while retaining a single final verification scan. The findings indicate that AR navigation enhances first-pass precision, reduces procedural variability, and improves workflow efficiency, supporting its potential clinical value for more consistent and efficient minimally invasive interventions.

Biomedical Physics & Engineering Express
Fujian Medical University (CN), Fujian Provincial Cancer Hospital (CN), Fuzhou University (CN)
Openalex Percentile: Top 5%
Augmented Reality Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Display-Based Augmented Reality Navigation for CT-Guided Thoracoabdominal Punctures: Phantom Study of Accuracy and Workflow Efficiency — Penggang Bai, Zhuting Fang, et al. · Biomedical Physics & Engineering Express (2026) | TGRS Research Map | TGRS