Intraindividual comparison of photon-counting detector CT and third-generation dual-source energy-integrating detector CT in multiphasic contrast-enhanced abdominal CT

This study aimed to compare image quality between photon-counting detector computed tomography (PCD-CT) and third-generation dual-source energy-integrating detector CT (EID-CT) in multiphasic contrast-enhanced abdominal imaging using intraindividual analysis. This retrospective study included 88 patients who underwent both arterial phase (AP) and portal venous phase (PVP) abdominal CT with PCD-CT and EID-CT. Virtual monoenergetic images (VMIs) from 50 to 90 keV were reconstructed in PCD-CT, and 120 kVp images were applied in EID-CT. Quantitative image analysis evaluated CT attenuation, image noise, and contrast-to-noise ratio (CNR) in abdominal organs and vessels. Qualitative image quality, including vessel and parenchymal contrast, noise, and overall image quality, was assessed by two radiologists using a 5-point Likert scale. Compared with EID-CT, VMIs at 50–70 keV obtained from PCD-CT demonstrated significantly higher CT attenuation values (P < 0.001) across all evaluated abdominal organs and vessels. CNRs at 70 keV were significantly greater than those in EID-CT for all objects (P < 0.001), with increases of 13.3‒41.6% on AP and 40.4‒49.3% on PVP. Image noise in 70 keV VMI was lower than EID-CT (P < 0.001). Optimal image quality was achieved using VMIs at 60–70 keV, which achieved significantly higher qualitative scores (P < 0.001) than those from EID-CT. Substantial interobserver agreement was observed (κ = 0.60–0.79). The CT dose volume index was slightly lower with PCD-CT compared with EID-CT (P < 0.001), whereas dose-length product values remained similar. PCD-CT significantly improved image quality in multiphasic abdominal CT compared with third-generation dual-source EID-CT under equivalent radiation dose conditions. The superior iodine enhancement and higher CNR in VMIs at 60–70 keV highlight the advantages of PCD-CT.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-03-26
DOI
https://doi.org/10.1038/s41598-026-44618-x
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraindividual comparison of photon-counting detector CT and third-generation dual-source energy-integrating detector CT in multiphasic contrast-enhanced abdominal CT

Noriyuki Negi, Eisuke Ueshima, Yoshiko Ueno, Takahiro Tsuboyama et al.
Scientific Reports
Advanced X-ray and CT Imaging
article

Intraindividual comparison of photon-counting detector CT and third-generation dual-source energy-integrating detector CT in multiphasic contrast-enhanced abdominal CT

Noriyuki Negi, Eisuke Ueshima, Yoshiko Ueno, Takahiro Tsuboyama, Izumi Imaoka, Kentaro Nishiuchi, Akihiro Umeno, Takeru Yamaguchi, Kazuki Ishikawa, Takamichi Murakami, Ryohei Kozuki, Keitaro Sofue
article en

Abstract

This study aimed to compare image quality between photon-counting detector computed tomography (PCD-CT) and third-generation dual-source energy-integrating detector CT (EID-CT) in multiphasic contrast-enhanced abdominal imaging using intraindividual analysis. This retrospective study included 88 patients who underwent both arterial phase (AP) and portal venous phase (PVP) abdominal CT with PCD-CT and EID-CT. Virtual monoenergetic images (VMIs) from 50 to 90 keV were reconstructed in PCD-CT, and 120 kVp images were applied in EID-CT. Quantitative image analysis evaluated CT attenuation, image noise, and contrast-to-noise ratio (CNR) in abdominal organs and vessels. Qualitative image quality, including vessel and parenchymal contrast, noise, and overall image quality, was assessed by two radiologists using a 5-point Likert scale. Compared with EID-CT, VMIs at 50–70 keV obtained from PCD-CT demonstrated significantly higher CT attenuation values (P < 0.001) across all evaluated abdominal organs and vessels. CNRs at 70 keV were significantly greater than those in EID-CT for all objects (P < 0.001), with increases of 13.3‒41.6% on AP and 40.4‒49.3% on PVP. Image noise in 70 keV VMI was lower than EID-CT (P < 0.001). Optimal image quality was achieved using VMIs at 60–70 keV, which achieved significantly higher qualitative scores (P < 0.001) than those from EID-CT. Substantial interobserver agreement was observed (κ = 0.60–0.79). The CT dose volume index was slightly lower with PCD-CT compared with EID-CT (P < 0.001), whereas dose-length product values remained similar. PCD-CT significantly improved image quality in multiphasic abdominal CT compared with third-generation dual-source EID-CT under equivalent radiation dose conditions. The superior iodine enhancement and higher CNR in VMIs at 60–70 keV highlight the advantages of PCD-CT.

Scientific Reports
Kobe University Hospital (JP), Kobe University (JP)
Affordable and clean energy
Openalex Percentile: Top 7%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.