Optimization of Region-of-Interest Configuration for Fractal Analysis of Peri-Implant Bone on Panoramic Radiographs

Objective: The aim of this study was to determine the optimal region-of-interest (ROI) pixel size for fractal dimension analysis on panoramic radiographs that best reflects implant stability assessed by resonance frequency analysis (ISQ) and to investigate whether implant stability can be directly estimated from radiographic images. Materials and Methods: This retrospective cross-sectional study included 65 patients for whom panoramic radiographs and resonance frequency analysis measurements were available. All panoramic images were converted to TIFF format and standardized to a resolution of 2627 × 1646 pixels. All radiographic images were obtained using the same panoramic imaging device and standardized acquisition protocol. Exposure parameters were adjusted within the manufacturer’s recommended range to ensure optimal image quality while maintaining methodological consistency across patients. During ROI selection, care was taken to avoid cortical bone margins, overlapping anatomical structures, and radiographic artifacts in order to ensure that the analyzed regions represented trabecular bone adjacent to the implant surface. Fractal dimension analysis was performed in the cervical peri-implant bone region, starting from the first bone–implant contact and extending apically, using three different ROI configurations. The ROI size was defined as 30 pixels apically and 10 pixels horizontally for FMD1, 30 × 20 pixels for FMD2, and 30 × 30 pixels for FMD3. Implant stability was assessed using ISQ values. Data distribution was evaluated using the Shapiro–Wilk test. Associations between ISQ and fractal dimension measurements were analyzed using Pearson and Spearman correlation analyses. Multiple linear regression models adjusted for age and sex were constructed to assess independent associations. Results: The mean age of the participants was 50.0 ± 9.9 years, and the mean ISQ value was 78.6 ± 5.9. The mean fractal dimension values were 1.466 ± 0.055 for FMD1, 1.595 ± 0.031 for FMD2, and 1.655 ± 0.046 for FMD3. No significant association was found between ISQ and FMD1 or FMD3. A weak positive correlation was observed between ISQ and FMD2; however, this association did not remain statistically significant after correction for multiple comparisons. In multiple linear regression analysis, ISQ was identified as an independent predictor of FMD2, but not of FMD1 or FMD3. Age and sex had no significant effect on fractal dimension measurements. Conclusions: Fractal dimension measurements derived from panoramic radiographs showed a weak association with implant stability that was dependent on the selected ROI pixel size. Among the evaluated configurations, the 30 × 20-pixel ROI at the cervical peri-implant region demonstrated the strongest association with ISQ values, suggesting that this ROI configuration showed the most consistent association with ISQ values among the tested ROI sizes.

Authors

Institutions

Publication Details

Journal
Fractal and Fractional
Published
2026-03-26
DOI
https://doi.org/10.3390/fractalfract10040215
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Region-of-Interest Configuration for Fractal Analysis of Peri-Implant Bone on Panoramic Radiographs

Nezif Çelik, Devrim Deniz Üner, Bozan Serhat İzol, Remzi Boynukara
Fractal and Fractional
Dental Radiography and Imaging
article

Optimization of Region-of-Interest Configuration for Fractal Analysis of Peri-Implant Bone on Panoramic Radiographs

Nezif Çelik, Devrim Deniz Üner, Bozan Serhat İzol, Remzi Boynukara
article en

Abstract

Objective: The aim of this study was to determine the optimal region-of-interest (ROI) pixel size for fractal dimension analysis on panoramic radiographs that best reflects implant stability assessed by resonance frequency analysis (ISQ) and to investigate whether implant stability can be directly estimated from radiographic images. Materials and Methods: This retrospective cross-sectional study included 65 patients for whom panoramic radiographs and resonance frequency analysis measurements were available. All panoramic images were converted to TIFF format and standardized to a resolution of 2627 × 1646 pixels. All radiographic images were obtained using the same panoramic imaging device and standardized acquisition protocol. Exposure parameters were adjusted within the manufacturer’s recommended range to ensure optimal image quality while maintaining methodological consistency across patients. During ROI selection, care was taken to avoid cortical bone margins, overlapping anatomical structures, and radiographic artifacts in order to ensure that the analyzed regions represented trabecular bone adjacent to the implant surface. Fractal dimension analysis was performed in the cervical peri-implant bone region, starting from the first bone–implant contact and extending apically, using three different ROI configurations. The ROI size was defined as 30 pixels apically and 10 pixels horizontally for FMD1, 30 × 20 pixels for FMD2, and 30 × 30 pixels for FMD3. Implant stability was assessed using ISQ values. Data distribution was evaluated using the Shapiro–Wilk test. Associations between ISQ and fractal dimension measurements were analyzed using Pearson and Spearman correlation analyses. Multiple linear regression models adjusted for age and sex were constructed to assess independent associations. Results: The mean age of the participants was 50.0 ± 9.9 years, and the mean ISQ value was 78.6 ± 5.9. The mean fractal dimension values were 1.466 ± 0.055 for FMD1, 1.595 ± 0.031 for FMD2, and 1.655 ± 0.046 for FMD3. No significant association was found between ISQ and FMD1 or FMD3. A weak positive correlation was observed between ISQ and FMD2; however, this association did not remain statistically significant after correction for multiple comparisons. In multiple linear regression analysis, ISQ was identified as an independent predictor of FMD2, but not of FMD1 or FMD3. Age and sex had no significant effect on fractal dimension measurements. Conclusions: Fractal dimension measurements derived from panoramic radiographs showed a weak association with implant stability that was dependent on the selected ROI pixel size. Among the evaluated configurations, the 30 × 20-pixel ROI at the cervical peri-implant region demonstrated the strongest association with ISQ values, suggesting that this ROI configuration showed the most consistent association with ISQ values among the tested ROI sizes.

Fractal and FractionalVol. 10(4)
Bingöl University (TR), Harran University (TR)
Openalex Percentile: Top 5%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.