Generating patient-specific computational models with point cloud data from human atrial electrophysiology studies

One in five patients diagnosed with atrial fibrillation die within a year after being diagnosed according to a prospective cohort study done in the United Kingdom, making this disease the focus of many scientific studies. One approach to studying this disease has been computational models since they have demonstrated powerful capabilities in understanding and analyzing the biochemical processes underlying atrial fibrillation. To create accurate patient models for studying cardiovascular diseases, we developed a pipeline for generating patient-specific models of the left atrial posterior wall using point cloud data without image segmentation. Our goal was to evaluate the performance of these models by comparing simulated electrograms to those obtained from atrial fibrillation patients. We created models for two different paroxysmal atrial fibrillation patients under healthy tissue conditions. To validate our model, we compared simulated and measured electrograms using various metrics. Some electrograms matched well in terms of local activation time and cross-correlation peak, whereas others showed significant differences in amplitude and duration. Additionally, we explored the impact of modeling fibrotic tissue on electrogram morphology by creating four persistent atrial fibrillation patient models with varying fibrosis densities and types. Simulations indicated that increased modeled fibrosis density led to more multiphasic electrogram morphologies, with little impact from fibrosis type. The fibrosis simulations also had morphological characteristics seen in other fibrosis electrophysiology modeling studies like deflections patterns and amplitudes, strengthening the reasoning behind using this type of model generation methodology. Our findings suggest that point cloud data is sufficient for creating accurate left atrial posterior wall models, which can simulate electrograms comparable to measured waveforms. This method could be useful for patient-specific studies, potential specialized ablation procedures, and arrhythmia research.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-03-26
DOI
https://doi.org/10.1371/journal.pone.0344274
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Generating patient-specific computational models with point cloud data from human atrial electrophysiology studies

Laryssa Abdala, Boyce E. Griffith, Josue Nataren Moran
PLoS ONE
Atrial Fibrillation Management and Outcomes
article

Generating patient-specific computational models with point cloud data from human atrial electrophysiology studies

Laryssa Abdala, Boyce E. Griffith, Josue Nataren Moran
article en

Abstract

One in five patients diagnosed with atrial fibrillation die within a year after being diagnosed according to a prospective cohort study done in the United Kingdom, making this disease the focus of many scientific studies. One approach to studying this disease has been computational models since they have demonstrated powerful capabilities in understanding and analyzing the biochemical processes underlying atrial fibrillation. To create accurate patient models for studying cardiovascular diseases, we developed a pipeline for generating patient-specific models of the left atrial posterior wall using point cloud data without image segmentation. Our goal was to evaluate the performance of these models by comparing simulated electrograms to those obtained from atrial fibrillation patients. We created models for two different paroxysmal atrial fibrillation patients under healthy tissue conditions. To validate our model, we compared simulated and measured electrograms using various metrics. Some electrograms matched well in terms of local activation time and cross-correlation peak, whereas others showed significant differences in amplitude and duration. Additionally, we explored the impact of modeling fibrotic tissue on electrogram morphology by creating four persistent atrial fibrillation patient models with varying fibrosis densities and types. Simulations indicated that increased modeled fibrosis density led to more multiphasic electrogram morphologies, with little impact from fibrosis type. The fibrosis simulations also had morphological characteristics seen in other fibrosis electrophysiology modeling studies like deflections patterns and amplitudes, strengthening the reasoning behind using this type of model generation methodology. Our findings suggest that point cloud data is sufficient for creating accurate left atrial posterior wall models, which can simulate electrograms comparable to measured waveforms. This method could be useful for patient-specific studies, potential specialized ablation procedures, and arrhythmia research.

PLoS ONEVol. 21(3)
University of North Carolina at Chapel Hill (US), Duke University (US)
Openalex Percentile: Top 16%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.