Partial safety factor for seismic design of isolation systems consistent with second-generation Eurocode 8

A seismically isolated structure comprises the isolation system, the substructure and the superstructure. The design of the former is displacement-based, i.e., demand and capacity of the devices are in terms of displacement, subject to force constraints such as the transmission of vertical loads. Design of the latter is traditionally force-based, i.e., based on strength verifications of members. Design of the substructure is in between, with the sizing of the rattle-space being displacement-based and that of connection elements being force-based. International codes adopt different safety margins in the design of each of these three components. Sometimes, this leads to structures that, even though performing better than their fixed-base counterparts at lower intensities up to the design one, have a lower safety margin with respect to collapse. This paper focuses on the partial safety factor to be adopted in the design of the isolators’ displacement capacity. Values are derived to meet the Near Collapse reliability target set in the code, employing the same theoretical framework used to derive partial factors for displacement-based design of structural members in fixed-base structures, for the second-generation Eurocode 8. Even though seismic isolation can provide better-than-code performance, admitting some degree of damage allows relaxing design requirements to just match the regular code performance objective. Numerical assessment via multiple-stripe inelastic response history analyses, capable of considering the full range of phenomena occurring at higher than design seismic intensities, including device and super-structure damage, is thus used to show how the partial safety factor value can be reduced as a function of admissible (controlled) damage in the isolators.

Authors

Institutions

Publication Details

Journal
Bulletin of Earthquake Engineering
Published
2026-03-26
DOI
https://doi.org/10.1007/s10518-026-02437-5
Primary Topic
Nuclear Engineering Thermal-Hydraulics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Partial safety factor for seismic design of isolation systems consistent with second-generation Eurocode 8

Fabrizio Noto, Marco Furinghetti, Alberto Pavese, Paolo Franchin
Bulletin of Earthquake Engineering
Nuclear Engineering Thermal-Hydraulics
article

Partial safety factor for seismic design of isolation systems consistent with second-generation Eurocode 8

Fabrizio Noto, Marco Furinghetti, Alberto Pavese, Paolo Franchin
article en

Abstract

A seismically isolated structure comprises the isolation system, the substructure and the superstructure. The design of the former is displacement-based, i.e., demand and capacity of the devices are in terms of displacement, subject to force constraints such as the transmission of vertical loads. Design of the latter is traditionally force-based, i.e., based on strength verifications of members. Design of the substructure is in between, with the sizing of the rattle-space being displacement-based and that of connection elements being force-based. International codes adopt different safety margins in the design of each of these three components. Sometimes, this leads to structures that, even though performing better than their fixed-base counterparts at lower intensities up to the design one, have a lower safety margin with respect to collapse. This paper focuses on the partial safety factor to be adopted in the design of the isolators’ displacement capacity. Values are derived to meet the Near Collapse reliability target set in the code, employing the same theoretical framework used to derive partial factors for displacement-based design of structural members in fixed-base structures, for the second-generation Eurocode 8. Even though seismic isolation can provide better-than-code performance, admitting some degree of damage allows relaxing design requirements to just match the regular code performance objective. Numerical assessment via multiple-stripe inelastic response history analyses, capable of considering the full range of phenomena occurring at higher than design seismic intensities, including device and super-structure damage, is thus used to show how the partial safety factor value can be reduced as a function of admissible (controlled) damage in the isolators.

Bulletin of Earthquake Engineering
University of Pavia (IT), Engineering (Italy) (IT), European Centre for Training and Research in Earthquake Engineering (IT), Sapienza University of Rome (IT)
Openalex Percentile: Top 5%
Nuclear Engineering Thermal-Hydraulics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines