A Novel Microstrip Band-Stop Filter at 5.5 GHz for Non-Invasive Blood Glucose Monitoring

This work presents a novel compact size and sensitive band-stop filter, whose notch frequency is 5.5 GHz, and it is suggested to estimate the concentration of blood glucose non-invasively. The filter is made on FR-4, with the size of the entire structure being 15 mm × 25 mm × 1.6 mm. A human finger-phantom model, comprising layers of skin, fat, blood, and bone, is built in an EM simulation environment (HFSS) to assess the sensing performance of the human finger-phantom. The glucose content in the blood layer is kept at a range of 0 to 500 mg/dL, with the ratio of the resonant frequency shift being assessed by placing the finger phantom on the proposed filter structure. The sensing principle is based on the fact that the resonant frequency of the microwave sensor changes with changes in glucose concentration in the tissue, and this is due to the changes in the dielectric properties of the tissue. The shifts obtained in the study are used for the evaluation of glucose concentration in blood as a non-invasive technique. This work explores five microstrip band-stop filters noted as Designs I, II, III, IV, and V. In these filters, better results of minimum and maximum frequency shifts of 0.1 and 1.4 MHz in Design I and 0.1 and 2 MHz in Design IV are observed. The simulated results of Design IV are verified with measured results. Good matching is also noted at the lower frequencies. The filters are compact, cost-effective, and give better sensitivity performance. Hence, the proposed design can be used for glucose monitoring in blood samples involving a non-invasive method.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-03-26
DOI
https://doi.org/10.3390/app16073197
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Microstrip Band-Stop Filter at 5.5 GHz for Non-Invasive Blood Glucose Monitoring

Anveshkumar Nella, Ahmad A. Jiman, Rabah W. Aldhaheri, Jagadeesh Babu Kamili
Applied Sciences
Microwave and Dielectric Measurement Techniques
article

A Novel Microstrip Band-Stop Filter at 5.5 GHz for Non-Invasive Blood Glucose Monitoring

Anveshkumar Nella, Ahmad A. Jiman, Rabah W. Aldhaheri, Jagadeesh Babu Kamili
article en

Abstract

This work presents a novel compact size and sensitive band-stop filter, whose notch frequency is 5.5 GHz, and it is suggested to estimate the concentration of blood glucose non-invasively. The filter is made on FR-4, with the size of the entire structure being 15 mm × 25 mm × 1.6 mm. A human finger-phantom model, comprising layers of skin, fat, blood, and bone, is built in an EM simulation environment (HFSS) to assess the sensing performance of the human finger-phantom. The glucose content in the blood layer is kept at a range of 0 to 500 mg/dL, with the ratio of the resonant frequency shift being assessed by placing the finger phantom on the proposed filter structure. The sensing principle is based on the fact that the resonant frequency of the microwave sensor changes with changes in glucose concentration in the tissue, and this is due to the changes in the dielectric properties of the tissue. The shifts obtained in the study are used for the evaluation of glucose concentration in blood as a non-invasive technique. This work explores five microstrip band-stop filters noted as Designs I, II, III, IV, and V. In these filters, better results of minimum and maximum frequency shifts of 0.1 and 1.4 MHz in Design I and 0.1 and 2 MHz in Design IV are observed. The simulated results of Design IV are verified with measured results. Good matching is also noted at the lower frequencies. The filters are compact, cost-effective, and give better sensitivity performance. Hence, the proposed design can be used for glucose monitoring in blood samples involving a non-invasive method.

Applied SciencesVol. 16(7)
Dorset HealthCare University NHS Foundation Trust (GB), King Abdulaziz University (SA), Barkatullah University (IN)
Openalex Percentile: Top 7%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.