Study on the Thermal Deformation of Finger Seals Based on Local Thermal Non-Equilibrium in Porous Media

Finger seals operate over extended periods under complex conditions involving high-pressure differentials, elevated rotational speeds, and rotor radial runout. Intense convective heat transfer arises within the seal, significantly impacting its structural deformation. To elucidate the influence of temperature on finger-seal deformation during convective heat transfer, the present study derives heat transfer energy equations for finger seals based on the Local Thermal Non-Equilibrium (LTNE) model. A three-dimensional porous-media flow-field model incorporating the LTNE framework, along with a solid thermal-deformation model, is developed. The effects of pressure differential and interference-fit magnitude on the structural deformation and average contact pressure of finger seals are analyzed under both the Local Thermal Equilibrium (LTE) and LTNE models. The results indicate that the LTNE model predicts a higher maximum seal temperature and a lower leakage rate compared to the LTE model. In both models, the deformation of individual seal-blade layers increases with rising pressure differentials and interference-fit magnitudes. Furthermore, the overall blade deformation is more pronounced under the LTNE model, suggesting a substantial thermal influence on sealing performance. The effects of pressure difference and interference fit on the thermal deformation of the seal plate are similar: both have the greatest impact on radial deformation, followed by circumferential deformation and axial deformation. Within the pressure difference range, the radial deformation of the third-layer seal plate in the LTNE model increases by 14.55%. When the interference fit increases from 0.05 mm to 0.2 mm, the radial deformation of each layer of the seal plate in the LTNE model increases by 0.18 mm. The average contact pressure increases with both pressure differential and interference-fit magnitude across both models. At a given pressure differential, the LTNE model yields a higher average contact pressure than the LTE model, with a maximum observed difference of 0.01 MPa. When the interference-fit magnitude is small, the pressure difference between the models remains minimal; however, at the maximum interference-fit, the difference reaches 0.08 MPa.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-03-26
DOI
https://doi.org/10.3390/en19071639
Primary Topic
Tribology and Lubrication Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Thermal Deformation of Finger Seals Based on Local Thermal Non-Equilibrium in Porous Media

Altyib Abdallah Mahmoud Ahmed, Meihong Liu, Tingjun Zhang, Shixing Zhu et al.
Energies
Tribology and Lubrication Engineering
article

Study on the Thermal Deformation of Finger Seals Based on Local Thermal Non-Equilibrium in Porous Media

Altyib Abdallah Mahmoud Ahmed, Meihong Liu, Tingjun Zhang, Shixing Zhu, Juan Wang
article en

Abstract

Finger seals operate over extended periods under complex conditions involving high-pressure differentials, elevated rotational speeds, and rotor radial runout. Intense convective heat transfer arises within the seal, significantly impacting its structural deformation. To elucidate the influence of temperature on finger-seal deformation during convective heat transfer, the present study derives heat transfer energy equations for finger seals based on the Local Thermal Non-Equilibrium (LTNE) model. A three-dimensional porous-media flow-field model incorporating the LTNE framework, along with a solid thermal-deformation model, is developed. The effects of pressure differential and interference-fit magnitude on the structural deformation and average contact pressure of finger seals are analyzed under both the Local Thermal Equilibrium (LTE) and LTNE models. The results indicate that the LTNE model predicts a higher maximum seal temperature and a lower leakage rate compared to the LTE model. In both models, the deformation of individual seal-blade layers increases with rising pressure differentials and interference-fit magnitudes. Furthermore, the overall blade deformation is more pronounced under the LTNE model, suggesting a substantial thermal influence on sealing performance. The effects of pressure difference and interference fit on the thermal deformation of the seal plate are similar: both have the greatest impact on radial deformation, followed by circumferential deformation and axial deformation. Within the pressure difference range, the radial deformation of the third-layer seal plate in the LTNE model increases by 14.55%. When the interference fit increases from 0.05 mm to 0.2 mm, the radial deformation of each layer of the seal plate in the LTNE model increases by 0.18 mm. The average contact pressure increases with both pressure differential and interference-fit magnitude across both models. At a given pressure differential, the LTNE model yields a higher average contact pressure than the LTE model, with a maximum observed difference of 0.01 MPa. When the interference-fit magnitude is small, the pressure difference between the models remains minimal; however, at the maximum interference-fit, the difference reaches 0.08 MPa.

EnergiesVol. 19(7)
Kunming University of Science and Technology (CN), Civil Aviation University of China (CN), University of Nyala (SD)
Affordable and clean energy
Openalex Percentile: Top 7%
Tribology and Lubrication Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.