Individualized electrode subset improves the calibration accuracy of an EEG P300-design brain-computer interface for people with severe cerebral palsy

Introduction This study examined the effect of individualized electroencephalogram (EEG) electrode location selection for non-invasive P300-design brain-computer interfaces (BCIs) in people with varying severity of cerebral palsy (CP) in a post-hoc offline analysis. Methods A forward selection algorithm was used to select the best performing eight electrodes (of an available 32) to construct an individualized electrode subset for each participant. Custom electrode subset size was chosen to be 8 because BCI accuracy of the individualized subset was compared to accuracy of a widely used default subset. Results Across 51 participants, individualized subsets improved calibration accuracy only for the severe CP cohort (mean +28.6% absolute; 95% CI [13.4%, 46.1%]; p < 0.0001). No group-level benefit was detected for mild CP or typically developing controls, although several individuals in these groups improved (2/17 mild CP; 1/10 controls). In the subset with held-out testing data (mild CP and controls), calibration gains did not translate to higher testing accuracy; among controls, the subset effect was reduced on testing (−9.6%, 95% CI [−13.3%, −5.8%], p < 0.0001), with no evidence of change for mild CP. Participants with severe CP typically required larger subsets to approach asymptotic accuracy, whereas ≤ 8 electrodes were sufficient for most others. Discussion The findings suggested that electrode selection can accommodate atypical neuroanatomy in people with severe CP, while the default electrode locations are sufficient for people with milder impairments from CP and typically developing individuals.

Authors

Institutions

Publication Details

Journal
Frontiers in Human Neuroscience
Published
2026-03-26
DOI
https://doi.org/10.3389/fnhum.2026.1720969
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Individualized electrode subset improves the calibration accuracy of an EEG P300-design brain-computer interface for people with severe cerebral palsy

Jane E. Huggins, Petra Karlsson, Seth Warschausky, Si Long Jenny Tou
Frontiers in Human Neuroscience
EEG and Brain-Computer Interfaces
article

Individualized electrode subset improves the calibration accuracy of an EEG P300-design brain-computer interface for people with severe cerebral palsy

Jane E. Huggins, Petra Karlsson, Seth Warschausky, Si Long Jenny Tou
article en

Abstract

Introduction This study examined the effect of individualized electroencephalogram (EEG) electrode location selection for non-invasive P300-design brain-computer interfaces (BCIs) in people with varying severity of cerebral palsy (CP) in a post-hoc offline analysis. Methods A forward selection algorithm was used to select the best performing eight electrodes (of an available 32) to construct an individualized electrode subset for each participant. Custom electrode subset size was chosen to be 8 because BCI accuracy of the individualized subset was compared to accuracy of a widely used default subset. Results Across 51 participants, individualized subsets improved calibration accuracy only for the severe CP cohort (mean +28.6% absolute; 95% CI [13.4%, 46.1%]; p < 0.0001). No group-level benefit was detected for mild CP or typically developing controls, although several individuals in these groups improved (2/17 mild CP; 1/10 controls). In the subset with held-out testing data (mild CP and controls), calibration gains did not translate to higher testing accuracy; among controls, the subset effect was reduced on testing (−9.6%, 95% CI [−13.3%, −5.8%], p < 0.0001), with no evidence of change for mild CP. Participants with severe CP typically required larger subsets to approach asymptotic accuracy, whereas ≤ 8 electrodes were sufficient for most others. Discussion The findings suggested that electrode selection can accommodate atypical neuroanatomy in people with severe CP, while the default electrode locations are sufficient for people with milder impairments from CP and typically developing individuals.

Frontiers in Human NeuroscienceVol. 20
The University of Sydney (AU), Alliance University (IN), University of Toronto (CA), Cerebral Palsy Alliance (AU), University of Michigan (US), Interface (United States) (US)
Openalex Percentile: Top 11%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.