Incorporating Occupant Age Structure into Building Energy Simulation for Envelope Retrofit Evaluation in Existing Residential Buildings

The retrofit of existing residential buildings plays a critical role in reducing energy consumption and carbon emissions in the building sector. However, previous retrofit evaluations often fail to account for the age-related thermal and lighting requirements of residents in aging residential buildings, thereby overlooking the substantial behavioral heterogeneity that shapes retrofit effectiveness. This study evaluates the comprehensive performance of different building envelope retrofit strategies, considering occupants’ thermal and visual comfort, from the perspectives of energy efficiency, economic feasibility, and environmental sustainability. First, age-specific differences in occupancy patterns, thermal preferences, and lighting requirements between elderly and non-elderly comparison group occupants were systematically extracted from the literature. Then, a typical high-rise residential building was modeled in EnergyPlus to serve as the reference building, within which the differentiated occupant behavior models were implemented, and the pre-retrofit condition was defined as the baseline scenario. Next, six commonly applied exterior wall insulation materials and different glass configurations and window frames were parameterized and evaluated under varying insulation thicknesses and remaining building service life scenarios. Finally, the energy-saving performance, economic benefits, and carbon reduction potential of envelope retrofit measures were quantitatively assessed across three primary functional zones (bedroom, living room, and study), using area-normalized indicators. The results indicate that, in the retrofit of existing residential buildings, bedrooms and study rooms exhibit greater retrofit benefits than living rooms, primarily due to longer occupancy durations and higher heating demand. In terms of retrofit strategies, exterior wall insulation consistently outperforms window retrofitting in energy-saving potential, with energy-saving rates of approximately 3.2–4.3% depending on functional zone, material type, and insulation thickness. Among the evaluated materials, vitrified microbead insulation performs best overall in terms of energy, economic, and carbon benefits at 40–60 mm thickness. These findings support occupant-informed, low-carbon retrofit decision-making for existing residential buildings.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-03-26
DOI
https://doi.org/10.3390/buildings16071323
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incorporating Occupant Age Structure into Building Energy Simulation for Envelope Retrofit Evaluation in Existing Residential Buildings

Han Lin, Yutong Tan, Zexin Man, Zhengtao Ai et al.
Buildings
Building Energy and Comfort Optimization
article

Incorporating Occupant Age Structure into Building Energy Simulation for Envelope Retrofit Evaluation in Existing Residential Buildings

Han Lin, Yutong Tan, Zexin Man, Zhengtao Ai, Rongpeng Zhang
article en

Abstract

The retrofit of existing residential buildings plays a critical role in reducing energy consumption and carbon emissions in the building sector. However, previous retrofit evaluations often fail to account for the age-related thermal and lighting requirements of residents in aging residential buildings, thereby overlooking the substantial behavioral heterogeneity that shapes retrofit effectiveness. This study evaluates the comprehensive performance of different building envelope retrofit strategies, considering occupants’ thermal and visual comfort, from the perspectives of energy efficiency, economic feasibility, and environmental sustainability. First, age-specific differences in occupancy patterns, thermal preferences, and lighting requirements between elderly and non-elderly comparison group occupants were systematically extracted from the literature. Then, a typical high-rise residential building was modeled in EnergyPlus to serve as the reference building, within which the differentiated occupant behavior models were implemented, and the pre-retrofit condition was defined as the baseline scenario. Next, six commonly applied exterior wall insulation materials and different glass configurations and window frames were parameterized and evaluated under varying insulation thicknesses and remaining building service life scenarios. Finally, the energy-saving performance, economic benefits, and carbon reduction potential of envelope retrofit measures were quantitatively assessed across three primary functional zones (bedroom, living room, and study), using area-normalized indicators. The results indicate that, in the retrofit of existing residential buildings, bedrooms and study rooms exhibit greater retrofit benefits than living rooms, primarily due to longer occupancy durations and higher heating demand. In terms of retrofit strategies, exterior wall insulation consistently outperforms window retrofitting in energy-saving potential, with energy-saving rates of approximately 3.2–4.3% depending on functional zone, material type, and insulation thickness. Among the evaluated materials, vitrified microbead insulation performs best overall in terms of energy, economic, and carbon benefits at 40–60 mm thickness. These findings support occupant-informed, low-carbon retrofit decision-making for existing residential buildings.

BuildingsVol. 16(7)
Hunan University (CN), China International Science and Technology Cooperation (CN), China Energy Engineering Corporation (China) (CN)
Openalex Percentile: Top 7%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.