Postheating Compressive Behavior of Carbon Fiber–Wrapped, Geopolymer Concrete–Filled GFRP Composite Tubes after Elevated-Temperature Exposure

Glass fiber polymer–reinforced (GFRP) composite profiles offer advantages such as corrosion resistance and a favorable strength-to-weight ratio, but their limited ductility and poor fire resistance hinder broader structural use. This study examines the thermal and compressive behavior of carbon fiber–reinforced polymer (CFRP)–confined, geopolymer concrete–filled pultruded GFRP square tubes under elevated temperatures. A total of 90 specimens were prepared using geopolymer concrete with three different compressive strengths (average strengths of 59.8, 68.3, and 89.6 MPa), controlled by sodium hydroxide molarity: 4 M (geopolymer concrete with 4 M sodium hydroxide, denoted as GC4), 8 M (GC8), and 12 M (GC12). Specimens were externally wrapped with CFRP wraps and exposed to temperatures ranging from 25°C to 350°C. Results show that CFRP confinement significantly enhanced compressive capacity, particularly in lower-strength cores, with average strength gains of 87%, 63%, and 27% for GC4, GC8, and GC12 specimens, respectively. Interestingly, elevated temperatures improved strength further, with peak load increases of up to 25% at 350°C. Average ductility indices decreased with increasing concrete strength, ranging from 1.42 (GC4) to 1.30 (GC12). One-way ANOVA revealed that temperature accounted for 82%, 79%, and 63% of variance in compressive capacity for GC4, GC8, and GC12 groups, respectively. These findings highlight the effectiveness of CFRP confinement and the potential of sustainable geopolymer-filled GFRP systems in fire-prone structural applications.

Authors

Institutions

Publication Details

Journal
Journal of Composites for Construction
Published
2026-03-26
DOI
https://doi.org/10.1061/jccof2.cceng-5449
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Postheating Compressive Behavior of Carbon Fiber–Wrapped, Geopolymer Concrete–Filled GFRP Composite Tubes after Elevated-Temperature Exposure

Milad Shakiba, Milad Bazli, Zahir Azimi, Amir Siavoshi et al.
Journal of Composites for Construction
Fire effects on concrete materials
article

Postheating Compressive Behavior of Carbon Fiber–Wrapped, Geopolymer Concrete–Filled GFRP Composite Tubes after Elevated-Temperature Exposure

Milad Shakiba, Milad Bazli, Zahir Azimi, Amir Siavoshi, Mohsen Ebrahimzadeh, Amin Jahedi Dalivand
article en

Abstract

Glass fiber polymer–reinforced (GFRP) composite profiles offer advantages such as corrosion resistance and a favorable strength-to-weight ratio, but their limited ductility and poor fire resistance hinder broader structural use. This study examines the thermal and compressive behavior of carbon fiber–reinforced polymer (CFRP)–confined, geopolymer concrete–filled pultruded GFRP square tubes under elevated temperatures. A total of 90 specimens were prepared using geopolymer concrete with three different compressive strengths (average strengths of 59.8, 68.3, and 89.6 MPa), controlled by sodium hydroxide molarity: 4 M (geopolymer concrete with 4 M sodium hydroxide, denoted as GC4), 8 M (GC8), and 12 M (GC12). Specimens were externally wrapped with CFRP wraps and exposed to temperatures ranging from 25°C to 350°C. Results show that CFRP confinement significantly enhanced compressive capacity, particularly in lower-strength cores, with average strength gains of 87%, 63%, and 27% for GC4, GC8, and GC12 specimens, respectively. Interestingly, elevated temperatures improved strength further, with peak load increases of up to 25% at 350°C. Average ductility indices decreased with increasing concrete strength, ranging from 1.42 (GC4) to 1.30 (GC12). One-way ANOVA revealed that temperature accounted for 82%, 79%, and 63% of variance in compressive capacity for GC4, GC8, and GC12 groups, respectively. These findings highlight the effectiveness of CFRP confinement and the potential of sustainable geopolymer-filled GFRP systems in fire-prone structural applications.

Journal of Composites for ConstructionVol. 30(3)
Sharif University of Technology (IR), The University of Queensland (AU), Kharazmi University (IR), University of Canterbury (NZ), Charles Darwin University (AU), Shahid Rajaee Teacher Training University (IR)
Responsible consumption and production
Openalex Percentile: Top 7%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.