MRI and Patient Reported Outcomes of a Hyaluronic Acid Based Rotator Cuff Augmentation Implant: A Pilot Case Series

Aims & Objectives Recent literature has focused on improving rotator cuff repair (RCR) healing rates by using “patches” of various properties. The purpose was to report on safety, efficacy, MRI imaging results, and patient reported outcome measures (PROMs) at 3 and 6 months for an FDA cleared Hyaluronic Acid (HA) based “patch” system. Materials & Methods A case series of 10 patients who underwent implantation with the HA patch for either full thickness tears (FT-RTC) or partial thickness tears (PT-RTC). Preoperative and postoperative PROMs including ASES, SANE, and PROMIS scores were collected. MRIs were compared between preop and postop at 3 months and 6 months. Results 10 patients were included: 4 underwent purely “onlay” repair for PT-RTC tear and 6 underwent “augmentation” after completion of FT-RTC repairs with the HA patch. Overall, patients had statistically significant improvements in SANE scores at 3 and 6 months postop (p=0.013 and p<0.001), ASES at 6 months (p<0.001), and PROMIS Physical at 6 months (p=0.004). Tendon thickness significantly increased from 4.77 ± 0.67 mm to 7.63 ± 1.30 mm and 7.61 ± 1.03 mm at 3 and 6 months, respectively (p<0.001). There was abundant subacromial healing response and a thickened layer of tendon-like tissue where the HA patch was placed at 3 months postop, with tissue appearing more organized and incorporated into the tendon at 6 months. There were no recurrent tears or complications. Conclusions This series demonstrates safety and efficacy when managing both PT-RTC and FT-RTC tears with an HA based patch. Keywords: Augmentation, Hyaluronic Acid, Patch, Rotator Cuff, Shoulder Level of Evidence IV, Case Series

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Experience & Innovation
Published
2026-03-26
DOI
https://doi.org/10.60118/001c.157512
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MRI and Patient Reported Outcomes of a Hyaluronic Acid Based Rotator Cuff Augmentation Implant: A Pilot Case Series

Raahil S. Patel, Viktoria Maria Sochor, Andrew Moore, Héctor Cardona et al.
Journal of Orthopaedic Experience & Innovation
Shoulder Injury and Treatment
article

MRI and Patient Reported Outcomes of a Hyaluronic Acid Based Rotator Cuff Augmentation Implant: A Pilot Case Series

Raahil S. Patel, Viktoria Maria Sochor, Andrew Moore, Héctor Cardona, Christopher P. Baker, Eric M. Cohen
article en

Abstract

Aims & Objectives Recent literature has focused on improving rotator cuff repair (RCR) healing rates by using “patches” of various properties. The purpose was to report on safety, efficacy, MRI imaging results, and patient reported outcome measures (PROMs) at 3 and 6 months for an FDA cleared Hyaluronic Acid (HA) based “patch” system. Materials & Methods A case series of 10 patients who underwent implantation with the HA patch for either full thickness tears (FT-RTC) or partial thickness tears (PT-RTC). Preoperative and postoperative PROMs including ASES, SANE, and PROMIS scores were collected. MRIs were compared between preop and postop at 3 months and 6 months. Results 10 patients were included: 4 underwent purely “onlay” repair for PT-RTC tear and 6 underwent “augmentation” after completion of FT-RTC repairs with the HA patch. Overall, patients had statistically significant improvements in SANE scores at 3 and 6 months postop (p=0.013 and p<0.001), ASES at 6 months (p<0.001), and PROMIS Physical at 6 months (p=0.004). Tendon thickness significantly increased from 4.77 ± 0.67 mm to 7.63 ± 1.30 mm and 7.61 ± 1.03 mm at 3 and 6 months, respectively (p<0.001). There was abundant subacromial healing response and a thickened layer of tendon-like tissue where the HA patch was placed at 3 months postop, with tissue appearing more organized and incorporated into the tendon at 6 months. There were no recurrent tears or complications. Conclusions This series demonstrates safety and efficacy when managing both PT-RTC and FT-RTC tears with an HA based patch. Keywords: Augmentation, Hyaluronic Acid, Patch, Rotator Cuff, Shoulder Level of Evidence IV, Case Series

Journal of Orthopaedic Experience & InnovationVol. 7(1)
University of South Florida (US), Florida Orthopaedic Institute (US), Foundation for Orthopaedic Research and Education (US)
Openalex Percentile: Top 7%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.