Establishment of High Channel‐Count Packaging in Active Implantable Medical Devices for Neuroprosthesis

Neuroprostheses have contributed extensively to humankind's capacity to treat disease and injury. Hearing loss is routinely overcome; pain is controlled; and myriad neurological, sensory, motor, and psychological disorders are managed through interventions involving neuromodulation. Fabrication of active implantable medical devices (AIMDs) often relies on highly skilled operators, leading to high costs, reliability challenges, and limitations to further device miniaturization and manufacturing output. Extending AIMD benefits to other disorders may also require a substantial increase in the number of stimulation or recording channels, exceeding the boundaries of existing fabrication techniques and human dexterity. In one-to-one correspondence, electrical signals must transition between the biological environment and a controlled atmosphere suitable for protecting active electronics-e.g., electrodes interfaced to excitable tissue must ultimately connect to a circuit node, each sensitive to corrosion or shorting when exposed to moisture and ions. Protection is typically achieved by hermetic encapsulation, with each signal crossing the hermetic barrier via a conductive pathway (feedthrough). As the quantity of signals increases, so does the complexity of the encapsulation. Herein, we describe a robust hermetic encapsulation approach with feedthrough densities of around 250 contacts/cm<sup>2</sup> and establishment of interconnections to each feedthrough in an all-at-once fashion. The resulting interfaces offer impedances < 5 mΩ between a connection pad of the electronics to the electrode and bond strengths ~10 MPa. An illustrative example is presented as a visual neuroprosthesis for retinal dystrophies with 99 channels of electrical stimulation and associated power and communication interfaces-a device that we call the Phoenix<sup>99</sup>.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2026-03-01
DOI
https://doi.org/10.1002/jbm.b.70040
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of High Channel‐Count Packaging in Active Implantable Medical Devices for Neuroprosthesis

Thomas Guenther, Gregg J. Suaning, Anne Vanhoestenberghe, Samuel C. Eggenberger et al.
Journal of Biomedical Materials Research Part B Applied Biomaterials
Neuroscience and Neural Engineering
article

Establishment of High Channel‐Count Packaging in Active Implantable Medical Devices for Neuroprosthesis

Thomas Guenther, Gregg J. Suaning, Anne Vanhoestenberghe, Samuel C. Eggenberger, Thomas C. Stieglitz, Orsolya Kékesi, Juan S. Ordonez, Nigel H. Lovell
article en

Abstract

Neuroprostheses have contributed extensively to humankind's capacity to treat disease and injury. Hearing loss is routinely overcome; pain is controlled; and myriad neurological, sensory, motor, and psychological disorders are managed through interventions involving neuromodulation. Fabrication of active implantable medical devices (AIMDs) often relies on highly skilled operators, leading to high costs, reliability challenges, and limitations to further device miniaturization and manufacturing output. Extending AIMD benefits to other disorders may also require a substantial increase in the number of stimulation or recording channels, exceeding the boundaries of existing fabrication techniques and human dexterity. In one-to-one correspondence, electrical signals must transition between the biological environment and a controlled atmosphere suitable for protecting active electronics-e.g., electrodes interfaced to excitable tissue must ultimately connect to a circuit node, each sensitive to corrosion or shorting when exposed to moisture and ions. Protection is typically achieved by hermetic encapsulation, with each signal crossing the hermetic barrier via a conductive pathway (feedthrough). As the quantity of signals increases, so does the complexity of the encapsulation. Herein, we describe a robust hermetic encapsulation approach with feedthrough densities of around 250 contacts/cm<sup>2</sup> and establishment of interconnections to each feedthrough in an all-at-once fashion. The resulting interfaces offer impedances < 5 mΩ between a connection pad of the electronics to the electrode and bond strengths ~10 MPa. An illustrative example is presented as a visual neuroprosthesis for retinal dystrophies with 99 channels of electrical stimulation and associated power and communication interfaces-a device that we call the Phoenix<sup>99</sup>.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 114(3)
University of Stuttgart (DE), The University of Sydney (AU), University of Freiburg (DE), King's College London (GB), UNSW Sydney (AU), Bernstein Center for Computational Neuroscience Freiburg (DE), Brain (Germany) (DE), Diabetes UK (GB)
Openalex Percentile: Top 8%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.