Cross-Modality Deep Learning Denoising for Low-Dose μSPECT: Transfer of PET-Trained U-Net and Diffusion Models

Reducing radiation dose in microsingle photon emission computed tomography (μSPECT) is essential to limit adverse biological effects in small animal studies, especially for longitudinal experiments. However, dose reduction increases noise and degrades image quality. While deep learning-based denoising (DL-DN) has shown promise for low-dose imaging, most prior work has focused on positron emission tomography (PET). DL-DN for μSPECT remains largely unexplored. In this study, we evaluate postreconstruction DL-DN for low-count μSPECT using two 2D architectures: a U-Net and a denoising diffusion probabilistic model (DDPM). To mitigate the limited availability of preclinical training data, we investigated transfer-learning from PET, a related molecular imaging modality, using models pretrained on both μPET (mouse) and clinical PET (human) data. These models were evaluated in a zero-shot setting and further adapted to the μSPECT domain via transfer-learning. Their performance was compared to models trained from scratch using varying amounts of μSPECT data (4–32 volumes). The data set consisted of in vivo mouse scans acquired with two tracers at 10%, 25%, and 50% of standard counts. Both architectures achieved meaningful noise reduction and improved quantitative agreement with standard-count references. Zero-shot PET-pretrained models demonstrated cross-modality generalization, reducing root mean squared error (RMSE) by more than 25% at the lowest count level, although residual artifacts remained due to differences between the PET source and μSPECT target domains. Transfer-learning consistently improved performance, yielding additional RMSE reductions exceeding 5% relative to zero-shot models. Its advantage over scratch-training decreased with increasing data set size, with maximal RMSE gains dropping from over 10% for small training sets to below 3% for larger data sets. Overall, the U-Net provided more robust performance with lower computational cost. These results indicate that DL-DN can support dose reduction in μSPECT, and that transfer-learning from PET offers a practical approach to address the small data set sizes common for preclinical settings.

Authors

Institutions

Publication Details

Journal
Chemical & Biomedical Imaging
Published
2026-03-26
DOI
https://doi.org/10.1021/cbmi.5c00270
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cross-Modality Deep Learning Denoising for Low-Dose μSPECT: Transfer of PET-Trained U-Net and Diffusion Models

Boxiao Yu, Kuang Gong, Florence M. Muller, Boris Vervenne et al.
Chemical & Biomedical Imaging
Medical Imaging Techniques and Applications
article

Cross-Modality Deep Learning Denoising for Low-Dose μSPECT: Transfer of PET-Trained U-Net and Diffusion Models

Boxiao Yu, Kuang Gong, Florence M. Muller, Boris Vervenne, Christian Vanhove, Sara Neyt, Maya Abi Akl, S. Vandenberghe, Elise Taragola
article en

Abstract

Reducing radiation dose in microsingle photon emission computed tomography (μSPECT) is essential to limit adverse biological effects in small animal studies, especially for longitudinal experiments. However, dose reduction increases noise and degrades image quality. While deep learning-based denoising (DL-DN) has shown promise for low-dose imaging, most prior work has focused on positron emission tomography (PET). DL-DN for μSPECT remains largely unexplored. In this study, we evaluate postreconstruction DL-DN for low-count μSPECT using two 2D architectures: a U-Net and a denoising diffusion probabilistic model (DDPM). To mitigate the limited availability of preclinical training data, we investigated transfer-learning from PET, a related molecular imaging modality, using models pretrained on both μPET (mouse) and clinical PET (human) data. These models were evaluated in a zero-shot setting and further adapted to the μSPECT domain via transfer-learning. Their performance was compared to models trained from scratch using varying amounts of μSPECT data (4–32 volumes). The data set consisted of in vivo mouse scans acquired with two tracers at 10%, 25%, and 50% of standard counts. Both architectures achieved meaningful noise reduction and improved quantitative agreement with standard-count references. Zero-shot PET-pretrained models demonstrated cross-modality generalization, reducing root mean squared error (RMSE) by more than 25% at the lowest count level, although residual artifacts remained due to differences between the PET source and μSPECT target domains. Transfer-learning consistently improved performance, yielding additional RMSE reductions exceeding 5% relative to zero-shot models. Its advantage over scratch-training decreased with increasing data set size, with maximal RMSE gains dropping from over 10% for small training sets to below 3% for larger data sets. Overall, the U-Net provided more robust performance with lower computational cost. These results indicate that DL-DN can support dose reduction in μSPECT, and that transfer-learning from PET offers a practical approach to address the small data set sizes common for preclinical settings.

Chemical & Biomedical Imaging
University of Architecture, Civil Engineering and Geodesy (BG), Ghent University Hospital (BE), University of Florida (US), California University of Pennsylvania (US)
Openalex Percentile: Top 9%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.