Evaluation of accuracy of two surgical guides in determining implant angulation: A clinical study

Objectives: To compare the accuracy of mesiodistal and buccolingual angulation of dental implants placed using two different surgical guide designs. Methods: Radiographic templates were fabricated and preoperative computed tomography scans were used to determine proposed implant angulations. Two types of surgical guides were utilized for implant placement. Postoperative CT scans were obtained and angular deviations were measured using Syngo-CT 2010B software. Statistical analysis was performed using Student’s t-test and Z-test. Results: Mean buccolingual angular deviation was 5.90 ± 3.27° for surgical guide-1 and 6.70 ± 2.64° for surgical guide-2. Mean mesiodistal angular deviation was 5.50 ± 2.83° for surgical guide-1 and 8.10 ± 4.45° for surgical guide-2. Intergroup differences were not statistically significant (p > 0.05). However, both guides demonstrated statistically significant deviations from the planned implant angulations. Conclusions: Both surgical guide systems exhibited comparable accuracy in implant placement. Nevertheless, clinically significant deviations from planned angulations were observed, highlighting the need for cautious interpretation of guided implant placement accuracy.

Authors

Institutions

Publication Details

Journal
Indian Journal of Dental Research
Published
2026-03-01
DOI
https://doi.org/10.4103/ijdr_202637s1_abs_161
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of accuracy of two surgical guides in determining implant angulation: A clinical study

G. Preethi
Indian Journal of Dental Research
Dental Implant Techniques and Outcomes
article

Evaluation of accuracy of two surgical guides in determining implant angulation: A clinical study

G. Preethi
article en

Abstract

Objectives: To compare the accuracy of mesiodistal and buccolingual angulation of dental implants placed using two different surgical guide designs. Methods: Radiographic templates were fabricated and preoperative computed tomography scans were used to determine proposed implant angulations. Two types of surgical guides were utilized for implant placement. Postoperative CT scans were obtained and angular deviations were measured using Syngo-CT 2010B software. Statistical analysis was performed using Student’s t-test and Z-test. Results: Mean buccolingual angular deviation was 5.90 ± 3.27° for surgical guide-1 and 6.70 ± 2.64° for surgical guide-2. Mean mesiodistal angular deviation was 5.50 ± 2.83° for surgical guide-1 and 8.10 ± 4.45° for surgical guide-2. Intergroup differences were not statistically significant (p > 0.05). However, both guides demonstrated statistically significant deviations from the planned implant angulations. Conclusions: Both surgical guide systems exhibited comparable accuracy in implant placement. Nevertheless, clinically significant deviations from planned angulations were observed, highlighting the need for cautious interpretation of guided implant placement accuracy.

Indian Journal of Dental ResearchVol. 37(Suppl 1)
Defence Research and Development Organisation (IN)
Openalex Percentile: Top 6%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of accuracy of two surgical guides in determining implant angulation: A clinical study — G. Preethi · Indian Journal of Dental Research (2026) | TGRS Research Map | TGRS