A multi-sensor informatics workflow for appliance-level energy use, comfort, and mixed-mode cooling in a composite-climate home

This study presents a year-long, multi-sensor residential monitoring dataset from a composite-climate home in Mohali, India, integrating appliance-level electricity use, indoor temperature–humidity measurements, and outdoor weather observations into an hourly residential energy informatics workflow. Nine appliances were monitored at 5-minute resolution and processed through a reproducible pipeline involving timestamp harmonization, anomaly handling, multi-source alignment, and feature extraction, yielding an analytics-ready dataset spanning 8,736 hourly observations (July 2024–June 2025). The monitored appliances consumed 845.25 kWh (58% of total household electricity use), with the refrigerator (21.95%) and air conditioner (cooling + heating; 19.07%) as the dominant monitored end uses. Psychrometric mapping quantified mixed-mode operation, distinguishing operating regions for Air Conditioner (AC) cooling (n=460 hours), evaporative cooling (n=172 hours), and AC heating (n=45 hours). Weather sensitivity analysis showed strong temperature dependence in baseline and seasonal loads (effect of outside temperature on refrigerator r=0.793; effect of outside temperature on geyser r=-0.694; slope -0.048 kWh/$$^{\circ }$$C), demonstrating the value of fusing weather variables into appliance analytics. Indoor comfort evaluation using the India Model for Adaptive Comfort (IMAC) indicated that 80.8% of summer hours and 51.7% of monsoon hours with valid measurements fell within adaptive comfort limits, with winter interpretation constrained by modeling assumptions and sensor availability. The primary contribution is a transparent, transferable workflow that converts heterogeneous residential sensing streams into a unified analytics dataset suitable for season-responsive appliance modeling, comfort-aware interpretation, and future multi-home deployments.

Authors

Institutions

Publication Details

Journal
Energy Informatics
Published
2026-03-26
DOI
https://doi.org/10.1186/s42162-026-00662-5
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A multi-sensor informatics workflow for appliance-level energy use, comfort, and mixed-mode cooling in a composite-climate home

Sahil Chilana, Aviruch Bhatia, Jyotirmay Mathur, Vishal Garg
Energy Informatics
Building Energy and Comfort Optimization
article

A multi-sensor informatics workflow for appliance-level energy use, comfort, and mixed-mode cooling in a composite-climate home

Sahil Chilana, Aviruch Bhatia, Jyotirmay Mathur, Vishal Garg
article en

Abstract

This study presents a year-long, multi-sensor residential monitoring dataset from a composite-climate home in Mohali, India, integrating appliance-level electricity use, indoor temperature–humidity measurements, and outdoor weather observations into an hourly residential energy informatics workflow. Nine appliances were monitored at 5-minute resolution and processed through a reproducible pipeline involving timestamp harmonization, anomaly handling, multi-source alignment, and feature extraction, yielding an analytics-ready dataset spanning 8,736 hourly observations (July 2024–June 2025). The monitored appliances consumed 845.25 kWh (58% of total household electricity use), with the refrigerator (21.95%) and air conditioner (cooling + heating; 19.07%) as the dominant monitored end uses. Psychrometric mapping quantified mixed-mode operation, distinguishing operating regions for Air Conditioner (AC) cooling (n=460 hours), evaporative cooling (n=172 hours), and AC heating (n=45 hours). Weather sensitivity analysis showed strong temperature dependence in baseline and seasonal loads (effect of outside temperature on refrigerator r=0.793; effect of outside temperature on geyser r=-0.694; slope -0.048 kWh/$$^{\circ }$$C), demonstrating the value of fusing weather variables into appliance analytics. Indoor comfort evaluation using the India Model for Adaptive Comfort (IMAC) indicated that 80.8% of summer hours and 51.7% of monsoon hours with valid measurements fell within adaptive comfort limits, with winter interpretation constrained by modeling assumptions and sensor availability. The primary contribution is a transparent, transferable workflow that converts heterogeneous residential sensing streams into a unified analytics dataset suitable for season-responsive appliance modeling, comfort-aware interpretation, and future multi-home deployments.

Energy Informatics
Department of Atomic Energy (IN), Malaviya National Institute of Technology Jaipur (IN)
Climate action
Openalex Percentile: Top 8%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.