Evaluation of passive fit of screw-retained digital fixed/detachable denture fabricated from poly-ether-ether-ketone material using conventional and digital methods (in-vitro study)

Abstract Aim: The aim of this in-vitro study was to evaluate the passive fit of screw-retained fixed/detachable digital denture framework fabricated from poly-ether-ether-ketone (PEEK) material using conventional and digital methods and comparing it with a denture framework fabricated from cobalt-chrome (Co-Cr) alloy. Material and methods: One readymade mandibular completely edentulous epoxy resin model covered with silicon resilient was used. Four implant analogs were placed at zero tilt on each cast multiunit abutments (MUA) and scanned with the epoxy resin cast by extra oral scanner and 3D virtual copy model was made. Outputting stereolithography (STL) file was saved and used as reference cast. The epoxy resin model with silicon was duplicated and poured in type IV stone that scanned and saved as STL file. Fourteen frameworks were designed as a duplication of the single ideal model and saved as STL file. Half of the frameworks were fabricated digitally from Co-Cr and the other half from PEEK. Passive fit was assessed for all dentures framework by conventional method and digital method. In conventional assessment of passive fit one screw was tightened on one side and the marginal fit was evaluated on the other sides by measuring the gap between the edge of MUA and the framework. Digital assessment of passive fit was made by using computer-aided design/computer-aided manufacturing software program and superimposition was made with the software demonstrating the amount of deviations between the prostheses and reference cast. Results: The result of this in-vitro study showed a significant difference between the two different material frameworks (PEEK and Co-Cr) regarding the gap between MUA and framework. However, the gap value was less in PEEK than Co-Cr. Conclusions: It was concluded that denture framework fabricated from PEEK has better passive fit compared to denture framework fabricated from Co-Cr using conventional and the digital evaluation.

Authors

Institutions

Publication Details

Journal
Tanta Dental Journal
Published
2026-01-01
DOI
https://doi.org/10.4103/tdj.tdj_185_25
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of passive fit of screw-retained digital fixed/detachable denture fabricated from poly-ether-ether-ketone material using conventional and digital methods (in-vitro study)

Faten Ahmed Aboutaleb, Mohamed N. El Gendy, Ayah A. Tawfiq
Tanta Dental Journal
Dental Implant Techniques and Outcomes
article

Evaluation of passive fit of screw-retained digital fixed/detachable denture fabricated from poly-ether-ether-ketone material using conventional and digital methods (in-vitro study)

Faten Ahmed Aboutaleb, Mohamed N. El Gendy, Ayah A. Tawfiq
article en

Abstract

Abstract Aim: The aim of this in-vitro study was to evaluate the passive fit of screw-retained fixed/detachable digital denture framework fabricated from poly-ether-ether-ketone (PEEK) material using conventional and digital methods and comparing it with a denture framework fabricated from cobalt-chrome (Co-Cr) alloy. Material and methods: One readymade mandibular completely edentulous epoxy resin model covered with silicon resilient was used. Four implant analogs were placed at zero tilt on each cast multiunit abutments (MUA) and scanned with the epoxy resin cast by extra oral scanner and 3D virtual copy model was made. Outputting stereolithography (STL) file was saved and used as reference cast. The epoxy resin model with silicon was duplicated and poured in type IV stone that scanned and saved as STL file. Fourteen frameworks were designed as a duplication of the single ideal model and saved as STL file. Half of the frameworks were fabricated digitally from Co-Cr and the other half from PEEK. Passive fit was assessed for all dentures framework by conventional method and digital method. In conventional assessment of passive fit one screw was tightened on one side and the marginal fit was evaluated on the other sides by measuring the gap between the edge of MUA and the framework. Digital assessment of passive fit was made by using computer-aided design/computer-aided manufacturing software program and superimposition was made with the software demonstrating the amount of deviations between the prostheses and reference cast. Results: The result of this in-vitro study showed a significant difference between the two different material frameworks (PEEK and Co-Cr) regarding the gap between MUA and framework. However, the gap value was less in PEEK than Co-Cr. Conclusions: It was concluded that denture framework fabricated from PEEK has better passive fit compared to denture framework fabricated from Co-Cr using conventional and the digital evaluation.

Tanta Dental JournalVol. 23(1)
Tanta University (EG)
Openalex Percentile: Top 6%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of passive fit of screw-retained digital fixed/detachable denture fabricated from poly-ether-ether-ketone material using conventional and digital methods (in-vitro study) — Faten Ahmed Aboutaleb, Mohamed N. El Gendy, et al. · Tanta Dental Journal (2026) | TGRS Research Map | TGRS